<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="pt-BR">
	<id>https://wiki-ti.unesp.br/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=User</id>
	<title>wikiti - Contribuições do usuário [pt-br]</title>
	<link rel="self" type="application/atom+xml" href="https://wiki-ti.unesp.br/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=User"/>
	<link rel="alternate" type="text/html" href="https://wiki-ti.unesp.br/index.php/Especial:Contribui%C3%A7%C3%B5es/User"/>
	<updated>2026-10-12T07:06:42Z</updated>
	<subtitle>Contribuições do usuário</subtitle>
	<generator>MediaWiki 1.40.0</generator>
	<entry>
		<id>https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=1091</id>
		<title>Switch Extreme</title>
		<link rel="alternate" type="text/html" href="https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=1091"/>
		<updated>2026-06-03T19:04:43Z</updated>

		<summary type="html">&lt;p&gt;Guilherme.marques: Guilherme.marques moveu Restrito:Switch Extreme para seu redirecionamento Switch Extreme&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Extreme]]&lt;br /&gt;
&lt;br /&gt;
== Configuração Serial ==&lt;br /&gt;
&lt;br /&gt;
 Speed Bus: &#039;&#039;&#039;115200&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Comandos ==&lt;br /&gt;
&lt;br /&gt;
===Configurações Básicas===&lt;br /&gt;
 &lt;br /&gt;
Apaga todas as configurações do Switch&lt;br /&gt;
 unconfigure switch all&lt;br /&gt;
&lt;br /&gt;
Habilitar SSH&lt;br /&gt;
 enable ssh2&lt;br /&gt;
&lt;br /&gt;
Desabilitar Telnet&lt;br /&gt;
 disable telnet&lt;br /&gt;
&lt;br /&gt;
Remover todas as portas da VLAN default&lt;br /&gt;
&lt;br /&gt;
 configure vlan Default delete ports all&lt;br /&gt;
&lt;br /&gt;
Remover uma VLAN especifica&lt;br /&gt;
 &lt;br /&gt;
 configure vlan &amp;lt;vlan_name&amp;gt; delete ports all&lt;br /&gt;
&lt;br /&gt;
 delete vlan &amp;lt;vlan_name&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Configurar o nome do Switch&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysname &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Salvar configurações&lt;br /&gt;
&lt;br /&gt;
 save&lt;br /&gt;
&lt;br /&gt;
==== SNTP ====&lt;br /&gt;
&lt;br /&gt;
 enable sntp-client &lt;br /&gt;
&lt;br /&gt;
 configure sntp-client primary &#039;&#039;IP_DO_SERVIDOR_NTP&#039;&#039; vr VR-Default&lt;br /&gt;
&lt;br /&gt;
 configure sntp-client update-interval 30&lt;br /&gt;
&lt;br /&gt;
Definir TimeZone do Brasil&lt;br /&gt;
&lt;br /&gt;
 configure timezone name BRTZ -180 noautodst&lt;br /&gt;
&lt;br /&gt;
Horário de verão&lt;br /&gt;
&lt;br /&gt;
 configure timezone name BRTZ -180 autodst name DST 0 begins every third sunday october at 0 0 ends every third sunday february at 0 0&lt;br /&gt;
&lt;br /&gt;
=== Configuração de Portas ===&lt;br /&gt;
&lt;br /&gt;
Ativar porta&lt;br /&gt;
&lt;br /&gt;
 enable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Desativar uma porta&lt;br /&gt;
&lt;br /&gt;
 disable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Colocar um rótulo em uma porta do switch&lt;br /&gt;
 configure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; display-string &#039;&#039;NOME_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Informações detalhadas de porta&lt;br /&gt;
&lt;br /&gt;
  show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; information detail&lt;br /&gt;
&lt;br /&gt;
Retirar um rótulo em uma porta do switch&lt;br /&gt;
 unconfigure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; display-string&lt;br /&gt;
&lt;br /&gt;
Retirar uma descrição em uma porta do switch&lt;br /&gt;
 unconfigure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; description-string&lt;br /&gt;
&lt;br /&gt;
=== Nodealias ===&lt;br /&gt;
Utilize o comando para ter informações mais completas de uso das portas (mac, ip, vlan, etc). Não colocar as portas de link, para melhor localizar o equipamento dentro da topologia utilizada.&lt;br /&gt;
Também o número de maxentries é 8192 para todo o dispositivo, ou seja é o número máximo que é armazenado por slot, por exemplo, para um stack com 7 switches o valor para maxentries deveria ficar em torno de &#039;48&#039;.&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 configure nodealias ports [port_list | all] maxentries entries&lt;br /&gt;
 enable nodealias port [port_list | all]&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 show nodealias port all&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 show nodealias ip &#039;&#039;ENDEREÇO_IP&#039;&#039;&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
Para desfazer as configurações utilize:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
clear nodealias { ports [port_list | all] | alias-id alias_id }&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== VLANS ===&lt;br /&gt;
Criar VLAN&lt;br /&gt;
&lt;br /&gt;
 create vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; tag &#039;&#039;NUMERO_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Adicionar porta(s) a uma VLAN&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; add port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; [tagged | untagged]&lt;br /&gt;
&lt;br /&gt;
Verificar qual VLAN uma(s) porta pertence&lt;br /&gt;
&lt;br /&gt;
 show vlan port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; vlan&lt;br /&gt;
&lt;br /&gt;
=== Configurações de Rede / IP ===&lt;br /&gt;
Configurar um IP em uma VLAN do Switch&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; ipaddress &#039;&#039;ENDEREÇO_IP/MASCARA_CIDR&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Configurar gateway padrão&lt;br /&gt;
 configure iproute add default &#039;&#039;IP_DO_GATEWAY&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Verificar rotas&lt;br /&gt;
&lt;br /&gt;
 show iproute&lt;br /&gt;
&lt;br /&gt;
Configurar o servidor DNS&lt;br /&gt;
 configure dns-client add name-server &#039;&#039;IP_DO_DNS&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== DHCP Server no Switch ===&lt;br /&gt;
&lt;br /&gt;
Configurar um IP em uma VLAN do Switch. Será o gateway do DHCP.&lt;br /&gt;
&lt;br /&gt;
Habilitar o servidor DHCP e defina o intervalo de endereços IP que o servidor DHCP irá distribuir.&lt;br /&gt;
 enable dhcp vlan &amp;lt;nome&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-address-range &amp;lt;ip_inicial&amp;gt; - &amp;lt;ip_final&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-lease-timer &amp;lt;tempo_lease&amp;gt;&lt;br /&gt;
Configurar Opções Adicionais de DHCP&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-options default-gateway &amp;lt;ip_gateway&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-options dns-server primary &amp;lt;ip_dns&amp;gt;&lt;br /&gt;
 enable dhcp ports &amp;lt;num_porta&amp;gt; vlan &amp;lt;nome&amp;gt; &lt;br /&gt;
Para consultar a tabela de alocação:&lt;br /&gt;
&lt;br /&gt;
 show vlan &amp;lt;nome&amp;gt; dhcp-address-allocation&lt;br /&gt;
&lt;br /&gt;
===Comandos (SHOW) para verificações de configurações ===&lt;br /&gt;
 show accounts&lt;br /&gt;
&lt;br /&gt;
 show configuration&lt;br /&gt;
&lt;br /&gt;
 show version&lt;br /&gt;
&lt;br /&gt;
 show version images&lt;br /&gt;
&lt;br /&gt;
 show system&lt;br /&gt;
&lt;br /&gt;
 show switch&lt;br /&gt;
&lt;br /&gt;
 show switch management&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Verifica portas agregadas&lt;br /&gt;
 show sharing&lt;br /&gt;
&lt;br /&gt;
 show licenses&lt;br /&gt;
&lt;br /&gt;
 show time&lt;br /&gt;
&lt;br /&gt;
 show log&lt;br /&gt;
&lt;br /&gt;
 show vlan&lt;br /&gt;
&lt;br /&gt;
 show vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;PORTA&#039;&#039; no-refresh&lt;br /&gt;
&lt;br /&gt;
 show cli journal&lt;br /&gt;
&lt;br /&gt;
 history&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Verificar se o equipamento esta sendo gerenciado pela Cloud&lt;br /&gt;
 show iqagent&lt;br /&gt;
&lt;br /&gt;
 show iqagent discovery detail&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Mostra tabela ARP&lt;br /&gt;
 show iparp&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Mostra informações de status (up/down) das portas&lt;br /&gt;
 show ports information detail | include Port:|Link\sState:|Link\sUps:|Link\sDowns&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Monitorar o tráfego de entrada e saída de uma VLAN&lt;br /&gt;
Habilitar o monitoramento na VLAN desejada:&lt;br /&gt;
 configure ports all monitor vlan &amp;lt;vlan_name&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Ver as informações da VLAN:&lt;br /&gt;
 show vlan statistics no-refresh&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==== Tabelas MAC / VLAN / Portas ====&lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;ENDERECO_MAC&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Para obter informações de mais do que um endereço, coloque os mac&#039;s entre aspas duplas, separados por um pipe &#039;|&#039;, por exemplo:&lt;br /&gt;
&lt;br /&gt;
 show fdb | include &amp;quot;ENDERECO_MAC1|ENDERECO_MAC2|ENDERECO_MAC3|....&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;PORTA_DO_SWITCH&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 show fdb vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== Empilhamento ===&lt;br /&gt;
&lt;br /&gt;
Para configurar uma nova pilha:&lt;br /&gt;
&lt;br /&gt;
1- Conecte fisicamente os nós usando as portas de empilhamento.&lt;br /&gt;
&lt;br /&gt;
2- Ligue os nós.&lt;br /&gt;
&lt;br /&gt;
3- Para cada switch no qual as portas de stacking ainda não estão ativadas, emita o comando:&lt;br /&gt;
&lt;br /&gt;
 enable stacking-support&lt;br /&gt;
&lt;br /&gt;
4- Verifique se todos os switches têm o mesmo protocolo de empilhamento e suporte&lt;br /&gt;
de empilhamento configurados.&lt;br /&gt;
&lt;br /&gt;
5- Efetue login em qualquer um dos nós através da porta do console, de preferência&lt;br /&gt;
aquela que você deseja usar como mestre. Se você planeja usar o Easy Setup, efetue&lt;br /&gt;
login no nó Master pretendido. Se a pilha for uma nova pilha, os parâmetros padrão&lt;br /&gt;
estão em vigor.&lt;br /&gt;
&lt;br /&gt;
6- Para verificar a pilha digite:&lt;br /&gt;
 show stacking&lt;br /&gt;
O comando “show stacking” exibe todos os nós na pilha. Todos os nós estão em um estado desativado e todos os nós aparecem como nós principais.&lt;br /&gt;
&lt;br /&gt;
7- Digite no switch Master.&lt;br /&gt;
 enable stacking&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Nota:&#039;&#039;&#039; &#039;&#039;Todos os switches devem ter o suporte de empilhamento ativado, mas&lt;br /&gt;
desabilitado, antes de executar o Easy Setup.&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
8- Este comando apresenta a opção de usar o procedimento de instalação fácil. Digite&lt;br /&gt;
 configure stacking easy-setup&lt;br /&gt;
&lt;br /&gt;
9- Reinicie o stack e digite:&lt;br /&gt;
 reboot stack-topology&lt;br /&gt;
&lt;br /&gt;
A configuração é definida como&lt;br /&gt;
valores padrão ao entrar no modo de empilhamento, portanto, todas as informações de&lt;br /&gt;
configuração inseridas anteriormente (exceto os parâmetros de empilhamento com&lt;br /&gt;
base na NVRAM, a imagem selecionada e as informações da conta à prova de falhas) não&lt;br /&gt;
estão disponíveis.&lt;br /&gt;
10- Faça login no nó Master pretendido e verifique os comandos do tipo de pilha &lt;br /&gt;
 show stacking&lt;br /&gt;
 show slot &lt;br /&gt;
 show stacking configuration&lt;br /&gt;
&lt;br /&gt;
11- Se a configuração da pilha for bem-sucedida:&lt;br /&gt;
- Todos os nós são visíveis na pilha.&lt;br /&gt;
- Todos os nós passam para o estado ativo.&lt;br /&gt;
- Algum tempo depois que os nós se tornam ativos, cada nó está presente no slot configurado.&lt;br /&gt;
- Depois que as funções são finalizadas, você pode ver um nó Master e um nó backup.&lt;br /&gt;
12- Verifique se o nó Master é o que você pretendia ser o Master.&lt;br /&gt;
&lt;br /&gt;
=== PoE ===&lt;br /&gt;
&lt;br /&gt;
PoE vem habilitado por padrão nos switches Extreme, para desabilitar, utilize os comandos:&lt;br /&gt;
&lt;br /&gt;
 disable inline-power&lt;br /&gt;
&lt;br /&gt;
 disable inline-power slot &amp;lt;slot&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 disable inline-power ports &amp;lt;port&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Verificando estatísticas da porta visando identificar problemas&lt;br /&gt;
&lt;br /&gt;
 show inline-power&lt;br /&gt;
 show inline-power configuration ports&lt;br /&gt;
 show inline-power info detail ports&lt;br /&gt;
 show inline-power stats ports&lt;br /&gt;
&lt;br /&gt;
O comando de &amp;quot;stats&amp;quot; possibilita identificar a classe do PD (Powered Device) definida em IEEE 802.3 (802.3af, 802.3at, 802.3bt) e associadas com níveis de potência específicas :&lt;br /&gt;
&lt;br /&gt;
    Class 0: Default for Type 1 PDs (802.3af), up to 13W.&lt;br /&gt;
    Class 1: Type 1 PD (802.3af), up to 3.84W.&lt;br /&gt;
    Class 2: Type 1 PD (802.3af), up to 6.49W.&lt;br /&gt;
    Class 3: Type 1 PD (802.3af), up to 13W.&lt;br /&gt;
    Class 4: Type 2 PD (802.3at PoE+), up to 25.5W.&lt;br /&gt;
    Class 5: Type 3 PD (802.3bt), up to 40W.&lt;br /&gt;
    Class 6: Type 3 PD (802.3bt), up to 51W.&lt;br /&gt;
    Class 7: Type 4 PD (802.3bt), up to 62W.&lt;br /&gt;
    Class 8: Type 4 PD (802.3bt), up to 71.3W.&lt;br /&gt;
&lt;br /&gt;
Por exemplo:&lt;br /&gt;
 # show inline-power stats ports 1:1-6&lt;br /&gt;
&lt;br /&gt;
                                STATISTICS COUNTERS&lt;br /&gt;
 Port     State         Class     Absent  InvSig   Denied    OverCurrent   Short&lt;br /&gt;
 1:1      delivering    class4        0       0       6          0             0&lt;br /&gt;
 1:2      searching     ------      113       0     118          0             0&lt;br /&gt;
 1:3      searching     ------        0     234       0          0             0&lt;br /&gt;
 1:4      searching     ------        0     226       0          0             0&lt;br /&gt;
 1:5      delivering    class2        1       5       7          0             0&lt;br /&gt;
 1:6      delivering    class2        0       0       6          0             0&lt;br /&gt;
&lt;br /&gt;
As colunas representam:&lt;br /&gt;
&lt;br /&gt;
#Absent: Exibe o número de vezes que a porta foi desconectada.&lt;br /&gt;
#InvSig: Exibe o número de vezes que a porta tinha uma assinatura inválida.&lt;br /&gt;
#Denied: Exibe o número de vezes que a porta foi negada.&lt;br /&gt;
#Over-current: Exibe o número de vezes que a porta entrou em um estado de sobrecorrente.&lt;br /&gt;
#Short: Exibe o número de vezes que a porta entrou no estado de corrente.&lt;br /&gt;
&lt;br /&gt;
(Fonte: https://documentation.extremenetworks.com/switchengine_commands_32.2/downloads/SwitchEngine_Command_Reference_32.2.pdf)&lt;br /&gt;
&lt;br /&gt;
===SNMP===&lt;br /&gt;
Desabilitar os protocolos SNMPv1/v2c&lt;br /&gt;
 disable snmp access snmp-v1v2c&lt;br /&gt;
&lt;br /&gt;
Configurar informações básicas do dispositivo&lt;br /&gt;
 configure snmp sysName &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysLocation &#039;&#039;LOCALIZAÇÃO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysContact &#039;&#039;CONTATO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Habilitar SNMPv3&lt;br /&gt;
 enable snmp access snmpv3&lt;br /&gt;
&lt;br /&gt;
Adicionar usuário SNMP&lt;br /&gt;
 configure snmpv3 add user &#039;&#039;USUARIO&#039;&#039;&lt;br /&gt;
                          {authentication [md5 | sha] &#039;&#039;SENHA_DE_AUTENTICAÇAO&#039;&#039;}&lt;br /&gt;
                          {privacy {des | 3des | aes {128 | 192 | 256}} &#039;&#039;SENHA_PRIVADA&#039;&#039;}&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add group &#039;&#039;NOME_DO_GRUPO&#039;&#039; user &#039;&#039;USUARIO&#039;&#039; sec-model usm&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add access &#039;&#039;NOME_DO_GRUPO&#039;&#039; sec-model usm sec-level &lt;br /&gt;
                  [noauth | authnopriv | priv] {read-view read_view_name} {write-viewwrite_view_name} {notify-view notify_view_name}&lt;br /&gt;
&lt;br /&gt;
===Diagnóstico de Cabos de Rede===&lt;br /&gt;
Para realizar o diagnóstico do cabo de rede&lt;br /&gt;
 run diagnostics cable ports &amp;lt;port&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Analise os resultados:&lt;br /&gt;
 Ok: Sem falhas detectadas.&lt;br /&gt;
 Open: Cabo desconectado, com quebra física ou má terminação.&lt;br /&gt;
 Short: Curto-circuito nos pares do cabo.&lt;br /&gt;
 Hi Imp / Low Imp: Problemas de impedância ou conector defeituoso. &lt;br /&gt;
&lt;br /&gt;
Diagnóstico de Hardware Geral (Extended)&lt;br /&gt;
Se a suspeita for um problema físico no módulo de fibra ou porta em si:&lt;br /&gt;
 run diagnostics extended.&lt;br /&gt;
Nota: Este comando pode interromper o tráfego por até 15 minutos. &lt;br /&gt;
&lt;br /&gt;
Diagnóstico de Fibra Óptica&lt;br /&gt;
Como o run diagnostics cable não funciona em fibra, para validar conectividade óptica, utilize: &lt;br /&gt;
 show port &amp;lt;port&amp;gt; information detail (Verifique se há luz/sinal e erros de CRC).&lt;br /&gt;
 show transceiver (Verifique a potência de recepção/transmissão - Tx/Rx power). &lt;br /&gt;
&lt;br /&gt;
Dica: O uso desse comando pode impactar o tráfego nas portas testadas temporariamente&lt;br /&gt;
&lt;br /&gt;
Para informações de diagnóstico detalhadas para transceivers ópticos, incluindo fabricante, serial, presença de sinal e status de falha de transmissão.&lt;br /&gt;
 debug hal show optic-info port-list 1:30&lt;br /&gt;
Analise do resultado:&lt;br /&gt;
 Port                       1:30&lt;br /&gt;
 SFP or SFP+ or SFP28:      SFP+&lt;br /&gt;
 Signal:                    present&lt;br /&gt;
 TX Fault:                  no&lt;br /&gt;
 Vendor:                    FORMERICAOE&lt;br /&gt;
 oui:                       00-00-00&lt;br /&gt;
 Part Number:               TAS-A1NB1-FAHM&lt;br /&gt;
 Serial Number:             23088-92224&lt;br /&gt;
 Manufacture Date:          230559&lt;br /&gt;
 Revision:&lt;br /&gt;
 SFP/SFP-DD/SFP+/SFP28 Type:SFP/SFP+/SFP28&lt;br /&gt;
 Connector:                 LC(7)&lt;br /&gt;
 Type:                      LR&lt;br /&gt;
 Supported:                 yes&lt;br /&gt;
 Wavelength:                1310&lt;br /&gt;
 Options[0]:                0x00&lt;br /&gt;
 Options[1]:                0x1a&lt;br /&gt;
 GBIC supports DDMI.  MonitorType: 68&lt;br /&gt;
&lt;br /&gt;
===Desinstalar licenças de avaliação===&lt;br /&gt;
Siga o processo descrito em: https://extreme-networks.my.site.com/ExtrArticleDetail?an=000092952&lt;br /&gt;
&lt;br /&gt;
== Segurança ==&lt;br /&gt;
&lt;br /&gt;
=== Habilitar Logs ===&lt;br /&gt;
 enable log target session&lt;br /&gt;
&lt;br /&gt;
 configure syslog add [ipaddress {udp-port {udp_port}} | ipPort | ipaddress tls_port {tls_port}] {vr vr_name} [local0...local7]&lt;br /&gt;
&lt;br /&gt;
 enable syslog&lt;br /&gt;
&lt;br /&gt;
==== Registrar alterações no Log ====&lt;br /&gt;
&lt;br /&gt;
Permite registrar em Log as mudanças de configuração, assim como quem realizou a modificação. Útil para fins de auditoria.&lt;br /&gt;
&lt;br /&gt;
  enable cli config-logging&lt;br /&gt;
&lt;br /&gt;
=== Habilitar Port-Security/MAC Locking ===&lt;br /&gt;
&lt;br /&gt;
MAC Locking, ou bloqueio de MAC, é uma funcionalidade que permite a um switch aprender e armazenar os endereços MAC dos dispositivos conectados a suas portas. Uma vez que um endereço MAC é aprendido, o switch pode bloquear a porta para novos dispositivos, impedindo conexões não autorizadas.&lt;br /&gt;
 configure mac-locking ports &amp;lt;num_porta&amp;gt; first-arrival limit-learning &amp;lt;limite_de_MACs_na_porta&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== DHCP/BOOTP Relay ===&lt;br /&gt;
&lt;br /&gt;
 enable bootprelay {{vlan} vlan_name | {{vr} vr_name} | all [{vr} vr_name]}&lt;br /&gt;
&lt;br /&gt;
 configure bootprelay {vlan &#039;&#039;NOME_DA_VLAN_DO_DHCP_SERVER&#039;&#039;} add &#039;&#039;IP_DO_DHCP&#039;&#039; {vr vrid}&lt;br /&gt;
&lt;br /&gt;
Verificar as configurações de DHCP/BootRelay&lt;br /&gt;
&lt;br /&gt;
 show bootprelay configuration&lt;br /&gt;
&lt;br /&gt;
 show configuration nettools&lt;br /&gt;
&lt;br /&gt;
=== DHCP Snooping ===&lt;br /&gt;
&lt;br /&gt;
 enable ip-security dhcp-snooping vlan &#039;&#039;ID_DA_VLAN&#039;&#039; port [&#039;&#039;all&#039;&#039; | &#039;&#039;PORTA(S)&#039;&#039;] violation-action none&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Configure trusted ports (uplink port for DHCP Server)&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 configure trusted-ports &#039;&#039;PORTAS_DE_UPLINK&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
 configure trusted-servers vlan &#039;&#039;ID_DA_VLAN_DO_DHCP_SERVER&#039;&#039; add server &#039;&#039;IP_DO_DHCP&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
=== Como Criar ACLs ===&lt;br /&gt;
&lt;br /&gt;
[https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html]&lt;br /&gt;
&lt;br /&gt;
=== Netlogin ===&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000080274 https://extremeportal.force.com/ExtrArticleDetail?an=000080274]&lt;br /&gt;
&lt;br /&gt;
[https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402 https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402 https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin]&lt;br /&gt;
&lt;br /&gt;
[https://github.com/dwinurhadia/freeradius-macauth https://github.com/dwinurhadia/freeradius-macauth]&lt;br /&gt;
&lt;br /&gt;
[https://wiki.freeradius.org/guide/Mac-Auth https://wiki.freeradius.org/guide/Mac-Auth]&lt;br /&gt;
&lt;br /&gt;
=== Configurando o MAC-BASED VLAN ===&lt;br /&gt;
1. Primeiro deve-se criar a VLAN temporária que o netlogin irá utilizar para &amp;quot;conversar com o Radius&amp;quot; e, também, a VLAN que será utilizada para atribuir IPs para os computadores:&lt;br /&gt;
&lt;br /&gt;
  create vlan &amp;quot;NET_LOGIN&amp;quot;&lt;br /&gt;
  create vlan &amp;quot;REDE_187&amp;quot;&lt;br /&gt;
  configure vlan REDE_187 tag 187&lt;br /&gt;
  configure REDE_187 add ports 24 tagged&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
2. Configurar a autenticação das portas para o netlogin:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin vlan NET_LOGIN&lt;br /&gt;
  enable netlogin dot1x mac&lt;br /&gt;
  configure netlogin mac authentication database-order radius&lt;br /&gt;
  enable netlogin ports 1-23 mac&lt;br /&gt;
  configure netlogin ports 1-23 mode port-based-vlans&lt;br /&gt;
  configure netlogin ports 1-23 no-restart&lt;br /&gt;
  configure netlogin add mac-list ff:ff:ff:ff:ff:ff 48&lt;br /&gt;
&lt;br /&gt;
Obs: o mac-list informado refere-se ao broadcast do MAC address e o valor &amp;quot;48&amp;quot; ao tamanho em bits&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
3. Configurar a autenticação do Radius:&lt;br /&gt;
&lt;br /&gt;
  configure radius mgmt-access primary server 200.145.x.y 1812 client-ip 172.31.x.y vr VR-Default&lt;br /&gt;
  configure radius mgmt-access primary shared-secret encrypted &amp;quot;#$8VnrPisKgrhPOCh2WEepV==&amp;quot;&lt;br /&gt;
  configure radius netlogin primary server 200.145.x.y 1812 client-ip 172.31.x.y vr VR-Default&lt;br /&gt;
  configure radius netlogin primary shared-secret encrypted &amp;quot;#$kyGEk8PK4BbzEV+WJdapp16A==&amp;quot;&lt;br /&gt;
  enable radius&lt;br /&gt;
  enable radius mgmt-access&lt;br /&gt;
  enable radius netlogin&lt;br /&gt;
&lt;br /&gt;
Obs: o endereço &amp;quot;primary server&amp;quot; é o servidor do radius, a porta &amp;quot;1812&amp;quot; é a porta padrão do Authentication. A shared-secret é gerada com o comando &#039;&#039;configure radius mgmt-access/netlogin primary shared-secret&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
4. Quando não há conexão disponível com o PFSense irá direcionar para a VLAN especificada, ideal é uma VLAN com acesso restrito:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin authentication failure vlan VLAN_restrita ports 1-23&lt;br /&gt;
  configure netlogin authentication service-unavailable vlan VLAN_restrita ports 1-23&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
5. Configuracao para reautenticacao do mac em segundos:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin mac ports all timers reauth-period 60&lt;br /&gt;
  configure netlogin mac ports all timers reauthentication on&lt;br /&gt;
&lt;br /&gt;
Após inserir esta opção, não é possível tirar, apenas desabilitar:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin mac ports 1-23 timers reauth-period 3600 reauthentication off&lt;br /&gt;
  configure netlogin mac timers reauth-period 0&lt;br /&gt;
  configure netlogin session-timeout mac 0&lt;br /&gt;
&lt;br /&gt;
6. Para retirar a configuração do NETLOGIN de alguma porta:&lt;br /&gt;
&lt;br /&gt;
  disable netlogin ports &amp;lt;portas&amp;gt; mac&lt;br /&gt;
&lt;br /&gt;
=== Configurando PFSense ===&lt;br /&gt;
1. No FreeRADIUS, na opção Users inserir as informações de conexão para o computador (MAC-Address, senha), além deste usuário, também é necessário criar o usuário de conexão da switch com a senha:&lt;br /&gt;
&lt;br /&gt;
2. No campo Additional RADIUS Attributes (REPLY-ITEM) inserir o comando &amp;quot;Extreme-Netlogin-Extended-VLAN = U187&amp;quot;, onde a letra U é para representar que esta é a VLAN do usuário e o número é a tag da VLAN:&lt;br /&gt;
&lt;br /&gt;
3. Em NAS/Clients inserir o endereço IP do SiteEngine (186.217.0.16) em Client IP Address, inserir a senha da switch em Client Shared Secret e no campo NAS Login informar o nome de usuário para conexão da switch.&lt;br /&gt;
&lt;br /&gt;
4. Na opção Interfaces inserir as informações de Authentication, Accounting e Status (IP e Porta Padrão)&lt;br /&gt;
&lt;br /&gt;
=== ELRP e STP ===&lt;br /&gt;
&lt;br /&gt;
Extreme Loop Recovery Protocol (ELRP) é um protocolo proprietário que detecta loops de rede na Camada 2. O ELRP envia uma PDU especial pela VLAN e detecta um loop se o remetente switch recebe a mesma PDU de volta&lt;br /&gt;
&lt;br /&gt;
1) Sugestão: Criar uma VLAN para aplicar o ELRP e STP. Ela não precisa existir na rede:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
create vlan STPDOMAIN tag 4000&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
2) Ativando o ELRP:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
enable elrp-client&lt;br /&gt;
configure elrp-client periodic vlan STPDOMAIN ports all disable-port duration 60&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
3) Configurando o stpd s0:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
disable stpd s0&lt;br /&gt;
configure stpd s0 mode dot1w&lt;br /&gt;
enable stpd s0 rapid-root-failover&lt;br /&gt;
enable stpd s0 auto-bind vlan STPDOMAIN&lt;br /&gt;
&lt;br /&gt;
configure stpd s0 ports link-type edge 1:1-24&lt;br /&gt;
configure stpd s0 ports edge-safeguard enable 1:1-24 recovery-timeout 60&lt;br /&gt;
configure stpd s0 ports bpdu-restrict enable 1:1-24 recovery-timeout 60&lt;br /&gt;
configure stpd s0 ports restricted-tcn on 1:1-24&lt;br /&gt;
&lt;br /&gt;
configure stpd s0 tag 4000&lt;br /&gt;
enable stpd s0&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* link-type edge: Define o tipo da porta [[auto | broadcast | point-to-point] port_list | edge port_list {edge-safeguard [enable | disable] {bpdu-restrict} {recovery-timeout seconds}}]&lt;br /&gt;
* edge-safeguard: - Previne LOOP no STPD&lt;br /&gt;
* bpdu-restrict: Impede que transmitido pacote BPDU nas portas (ligar outra Switch)&lt;br /&gt;
* restricted-tcn: Impede a propagação de BPDUs TCN na porta&lt;br /&gt;
&amp;lt;b&amp;gt;Se for realizar uplink via UTP, é necessário alterar as configurações acima para evitar que a porta seja desativada&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Para desabilitar BPDU nas portas:&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports link-type auto &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports edge-safeguard disable &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports bpdu-restrict disable &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== Bloqueio de endereços mac-ddress ===&lt;br /&gt;
&lt;br /&gt;
1. Pode ser utilizado o comando a seguir para criar uma lista BLACKHOLE, quando o bloqueio é específico dentro de uma VLAN:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
create fdb 01:00:5E:00:E0:00 vlan vlan_name [ports port_list | blackhole]&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
Para excluir utilize:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
delete fdb [all | mac_address [vlan vlan_name ] &lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
2. Caso o bloqueio desejado seja para qualquer VLAN existente, pode-se criar uma regra ACL:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
entry block_MAC {&lt;br /&gt;
      if { ethernet-source-address 01:00:5E:00:E0:00; } then { deny; }&lt;br /&gt;
}&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;/div&gt;</summary>
		<author><name>Guilherme.marques</name></author>
	</entry>
	<entry>
		<id>https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=1089</id>
		<title>Switch Extreme</title>
		<link rel="alternate" type="text/html" href="https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=1089"/>
		<updated>2026-06-03T19:03:23Z</updated>

		<summary type="html">&lt;p&gt;Guilherme.marques: Guilherme.marques moveu Switch Extreme para seu redirecionamento Restrito:Switch Extreme&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Extreme]]&lt;br /&gt;
&lt;br /&gt;
== Configuração Serial ==&lt;br /&gt;
&lt;br /&gt;
 Speed Bus: &#039;&#039;&#039;115200&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Comandos ==&lt;br /&gt;
&lt;br /&gt;
===Configurações Básicas===&lt;br /&gt;
 &lt;br /&gt;
Apaga todas as configurações do Switch&lt;br /&gt;
 unconfigure switch all&lt;br /&gt;
&lt;br /&gt;
Habilitar SSH&lt;br /&gt;
 enable ssh2&lt;br /&gt;
&lt;br /&gt;
Desabilitar Telnet&lt;br /&gt;
 disable telnet&lt;br /&gt;
&lt;br /&gt;
Remover todas as portas da VLAN default&lt;br /&gt;
&lt;br /&gt;
 configure vlan Default delete ports all&lt;br /&gt;
&lt;br /&gt;
Remover uma VLAN especifica&lt;br /&gt;
 &lt;br /&gt;
 configure vlan &amp;lt;vlan_name&amp;gt; delete ports all&lt;br /&gt;
&lt;br /&gt;
 delete vlan &amp;lt;vlan_name&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Configurar o nome do Switch&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysname &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Salvar configurações&lt;br /&gt;
&lt;br /&gt;
 save&lt;br /&gt;
&lt;br /&gt;
==== SNTP ====&lt;br /&gt;
&lt;br /&gt;
 enable sntp-client &lt;br /&gt;
&lt;br /&gt;
 configure sntp-client primary &#039;&#039;IP_DO_SERVIDOR_NTP&#039;&#039; vr VR-Default&lt;br /&gt;
&lt;br /&gt;
 configure sntp-client update-interval 30&lt;br /&gt;
&lt;br /&gt;
Definir TimeZone do Brasil&lt;br /&gt;
&lt;br /&gt;
 configure timezone name BRTZ -180 noautodst&lt;br /&gt;
&lt;br /&gt;
Horário de verão&lt;br /&gt;
&lt;br /&gt;
 configure timezone name BRTZ -180 autodst name DST 0 begins every third sunday october at 0 0 ends every third sunday february at 0 0&lt;br /&gt;
&lt;br /&gt;
=== Configuração de Portas ===&lt;br /&gt;
&lt;br /&gt;
Ativar porta&lt;br /&gt;
&lt;br /&gt;
 enable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Desativar uma porta&lt;br /&gt;
&lt;br /&gt;
 disable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Colocar um rótulo em uma porta do switch&lt;br /&gt;
 configure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; display-string &#039;&#039;NOME_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Informações detalhadas de porta&lt;br /&gt;
&lt;br /&gt;
  show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; information detail&lt;br /&gt;
&lt;br /&gt;
Retirar um rótulo em uma porta do switch&lt;br /&gt;
 unconfigure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; display-string&lt;br /&gt;
&lt;br /&gt;
Retirar uma descrição em uma porta do switch&lt;br /&gt;
 unconfigure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; description-string&lt;br /&gt;
&lt;br /&gt;
=== Nodealias ===&lt;br /&gt;
Utilize o comando para ter informações mais completas de uso das portas (mac, ip, vlan, etc). Não colocar as portas de link, para melhor localizar o equipamento dentro da topologia utilizada.&lt;br /&gt;
Também o número de maxentries é 8192 para todo o dispositivo, ou seja é o número máximo que é armazenado por slot, por exemplo, para um stack com 7 switches o valor para maxentries deveria ficar em torno de &#039;48&#039;.&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 configure nodealias ports [port_list | all] maxentries entries&lt;br /&gt;
 enable nodealias port [port_list | all]&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 show nodealias port all&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 show nodealias ip &#039;&#039;ENDEREÇO_IP&#039;&#039;&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
Para desfazer as configurações utilize:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
clear nodealias { ports [port_list | all] | alias-id alias_id }&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== VLANS ===&lt;br /&gt;
Criar VLAN&lt;br /&gt;
&lt;br /&gt;
 create vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; tag &#039;&#039;NUMERO_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Adicionar porta(s) a uma VLAN&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; add port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; [tagged | untagged]&lt;br /&gt;
&lt;br /&gt;
Verificar qual VLAN uma(s) porta pertence&lt;br /&gt;
&lt;br /&gt;
 show vlan port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; vlan&lt;br /&gt;
&lt;br /&gt;
=== Configurações de Rede / IP ===&lt;br /&gt;
Configurar um IP em uma VLAN do Switch&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; ipaddress &#039;&#039;ENDEREÇO_IP/MASCARA_CIDR&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Configurar gateway padrão&lt;br /&gt;
 configure iproute add default &#039;&#039;IP_DO_GATEWAY&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Verificar rotas&lt;br /&gt;
&lt;br /&gt;
 show iproute&lt;br /&gt;
&lt;br /&gt;
Configurar o servidor DNS&lt;br /&gt;
 configure dns-client add name-server &#039;&#039;IP_DO_DNS&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== DHCP Server no Switch ===&lt;br /&gt;
&lt;br /&gt;
Configurar um IP em uma VLAN do Switch. Será o gateway do DHCP.&lt;br /&gt;
&lt;br /&gt;
Habilitar o servidor DHCP e defina o intervalo de endereços IP que o servidor DHCP irá distribuir.&lt;br /&gt;
 enable dhcp vlan &amp;lt;nome&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-address-range &amp;lt;ip_inicial&amp;gt; - &amp;lt;ip_final&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-lease-timer &amp;lt;tempo_lease&amp;gt;&lt;br /&gt;
Configurar Opções Adicionais de DHCP&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-options default-gateway &amp;lt;ip_gateway&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-options dns-server primary &amp;lt;ip_dns&amp;gt;&lt;br /&gt;
 enable dhcp ports &amp;lt;num_porta&amp;gt; vlan &amp;lt;nome&amp;gt; &lt;br /&gt;
Para consultar a tabela de alocação:&lt;br /&gt;
&lt;br /&gt;
 show vlan &amp;lt;nome&amp;gt; dhcp-address-allocation&lt;br /&gt;
&lt;br /&gt;
===Comandos (SHOW) para verificações de configurações ===&lt;br /&gt;
 show accounts&lt;br /&gt;
&lt;br /&gt;
 show configuration&lt;br /&gt;
&lt;br /&gt;
 show version&lt;br /&gt;
&lt;br /&gt;
 show version images&lt;br /&gt;
&lt;br /&gt;
 show system&lt;br /&gt;
&lt;br /&gt;
 show switch&lt;br /&gt;
&lt;br /&gt;
 show switch management&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Verifica portas agregadas&lt;br /&gt;
 show sharing&lt;br /&gt;
&lt;br /&gt;
 show licenses&lt;br /&gt;
&lt;br /&gt;
 show time&lt;br /&gt;
&lt;br /&gt;
 show log&lt;br /&gt;
&lt;br /&gt;
 show vlan&lt;br /&gt;
&lt;br /&gt;
 show vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;PORTA&#039;&#039; no-refresh&lt;br /&gt;
&lt;br /&gt;
 show cli journal&lt;br /&gt;
&lt;br /&gt;
 history&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Verificar se o equipamento esta sendo gerenciado pela Cloud&lt;br /&gt;
 show iqagent&lt;br /&gt;
&lt;br /&gt;
 show iqagent discovery detail&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Mostra tabela ARP&lt;br /&gt;
 show iparp&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Mostra informações de status (up/down) das portas&lt;br /&gt;
 show ports information detail | include Port:|Link\sState:|Link\sUps:|Link\sDowns&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Monitorar o tráfego de entrada e saída de uma VLAN&lt;br /&gt;
Habilitar o monitoramento na VLAN desejada:&lt;br /&gt;
 configure ports all monitor vlan &amp;lt;vlan_name&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Ver as informações da VLAN:&lt;br /&gt;
 show vlan statistics no-refresh&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==== Tabelas MAC / VLAN / Portas ====&lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;ENDERECO_MAC&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Para obter informações de mais do que um endereço, coloque os mac&#039;s entre aspas duplas, separados por um pipe &#039;|&#039;, por exemplo:&lt;br /&gt;
&lt;br /&gt;
 show fdb | include &amp;quot;ENDERECO_MAC1|ENDERECO_MAC2|ENDERECO_MAC3|....&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;PORTA_DO_SWITCH&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 show fdb vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== Empilhamento ===&lt;br /&gt;
&lt;br /&gt;
Para configurar uma nova pilha:&lt;br /&gt;
&lt;br /&gt;
1- Conecte fisicamente os nós usando as portas de empilhamento.&lt;br /&gt;
&lt;br /&gt;
2- Ligue os nós.&lt;br /&gt;
&lt;br /&gt;
3- Para cada switch no qual as portas de stacking ainda não estão ativadas, emita o comando:&lt;br /&gt;
&lt;br /&gt;
 enable stacking-support&lt;br /&gt;
&lt;br /&gt;
4- Verifique se todos os switches têm o mesmo protocolo de empilhamento e suporte&lt;br /&gt;
de empilhamento configurados.&lt;br /&gt;
&lt;br /&gt;
5- Efetue login em qualquer um dos nós através da porta do console, de preferência&lt;br /&gt;
aquela que você deseja usar como mestre. Se você planeja usar o Easy Setup, efetue&lt;br /&gt;
login no nó Master pretendido. Se a pilha for uma nova pilha, os parâmetros padrão&lt;br /&gt;
estão em vigor.&lt;br /&gt;
&lt;br /&gt;
6- Para verificar a pilha digite:&lt;br /&gt;
 show stacking&lt;br /&gt;
O comando “show stacking” exibe todos os nós na pilha. Todos os nós estão em um estado desativado e todos os nós aparecem como nós principais.&lt;br /&gt;
&lt;br /&gt;
7- Digite no switch Master.&lt;br /&gt;
 enable stacking&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Nota:&#039;&#039;&#039; &#039;&#039;Todos os switches devem ter o suporte de empilhamento ativado, mas&lt;br /&gt;
desabilitado, antes de executar o Easy Setup.&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
8- Este comando apresenta a opção de usar o procedimento de instalação fácil. Digite&lt;br /&gt;
 configure stacking easy-setup&lt;br /&gt;
&lt;br /&gt;
9- Reinicie o stack e digite:&lt;br /&gt;
 reboot stack-topology&lt;br /&gt;
&lt;br /&gt;
A configuração é definida como&lt;br /&gt;
valores padrão ao entrar no modo de empilhamento, portanto, todas as informações de&lt;br /&gt;
configuração inseridas anteriormente (exceto os parâmetros de empilhamento com&lt;br /&gt;
base na NVRAM, a imagem selecionada e as informações da conta à prova de falhas) não&lt;br /&gt;
estão disponíveis.&lt;br /&gt;
10- Faça login no nó Master pretendido e verifique os comandos do tipo de pilha &lt;br /&gt;
 show stacking&lt;br /&gt;
 show slot &lt;br /&gt;
 show stacking configuration&lt;br /&gt;
&lt;br /&gt;
11- Se a configuração da pilha for bem-sucedida:&lt;br /&gt;
- Todos os nós são visíveis na pilha.&lt;br /&gt;
- Todos os nós passam para o estado ativo.&lt;br /&gt;
- Algum tempo depois que os nós se tornam ativos, cada nó está presente no slot configurado.&lt;br /&gt;
- Depois que as funções são finalizadas, você pode ver um nó Master e um nó backup.&lt;br /&gt;
12- Verifique se o nó Master é o que você pretendia ser o Master.&lt;br /&gt;
&lt;br /&gt;
=== PoE ===&lt;br /&gt;
&lt;br /&gt;
PoE vem habilitado por padrão nos switches Extreme, para desabilitar, utilize os comandos:&lt;br /&gt;
&lt;br /&gt;
 disable inline-power&lt;br /&gt;
&lt;br /&gt;
 disable inline-power slot &amp;lt;slot&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 disable inline-power ports &amp;lt;port&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Verificando estatísticas da porta visando identificar problemas&lt;br /&gt;
&lt;br /&gt;
 show inline-power&lt;br /&gt;
 show inline-power configuration ports&lt;br /&gt;
 show inline-power info detail ports&lt;br /&gt;
 show inline-power stats ports&lt;br /&gt;
&lt;br /&gt;
O comando de &amp;quot;stats&amp;quot; possibilita identificar a classe do PD (Powered Device) definida em IEEE 802.3 (802.3af, 802.3at, 802.3bt) e associadas com níveis de potência específicas :&lt;br /&gt;
&lt;br /&gt;
    Class 0: Default for Type 1 PDs (802.3af), up to 13W.&lt;br /&gt;
    Class 1: Type 1 PD (802.3af), up to 3.84W.&lt;br /&gt;
    Class 2: Type 1 PD (802.3af), up to 6.49W.&lt;br /&gt;
    Class 3: Type 1 PD (802.3af), up to 13W.&lt;br /&gt;
    Class 4: Type 2 PD (802.3at PoE+), up to 25.5W.&lt;br /&gt;
    Class 5: Type 3 PD (802.3bt), up to 40W.&lt;br /&gt;
    Class 6: Type 3 PD (802.3bt), up to 51W.&lt;br /&gt;
    Class 7: Type 4 PD (802.3bt), up to 62W.&lt;br /&gt;
    Class 8: Type 4 PD (802.3bt), up to 71.3W.&lt;br /&gt;
&lt;br /&gt;
Por exemplo:&lt;br /&gt;
 # show inline-power stats ports 1:1-6&lt;br /&gt;
&lt;br /&gt;
                                STATISTICS COUNTERS&lt;br /&gt;
 Port     State         Class     Absent  InvSig   Denied    OverCurrent   Short&lt;br /&gt;
 1:1      delivering    class4        0       0       6          0             0&lt;br /&gt;
 1:2      searching     ------      113       0     118          0             0&lt;br /&gt;
 1:3      searching     ------        0     234       0          0             0&lt;br /&gt;
 1:4      searching     ------        0     226       0          0             0&lt;br /&gt;
 1:5      delivering    class2        1       5       7          0             0&lt;br /&gt;
 1:6      delivering    class2        0       0       6          0             0&lt;br /&gt;
&lt;br /&gt;
As colunas representam:&lt;br /&gt;
&lt;br /&gt;
#Absent: Exibe o número de vezes que a porta foi desconectada.&lt;br /&gt;
#InvSig: Exibe o número de vezes que a porta tinha uma assinatura inválida.&lt;br /&gt;
#Denied: Exibe o número de vezes que a porta foi negada.&lt;br /&gt;
#Over-current: Exibe o número de vezes que a porta entrou em um estado de sobrecorrente.&lt;br /&gt;
#Short: Exibe o número de vezes que a porta entrou no estado de corrente.&lt;br /&gt;
&lt;br /&gt;
(Fonte: https://documentation.extremenetworks.com/switchengine_commands_32.2/downloads/SwitchEngine_Command_Reference_32.2.pdf)&lt;br /&gt;
&lt;br /&gt;
===SNMP===&lt;br /&gt;
Desabilitar os protocolos SNMPv1/v2c&lt;br /&gt;
 disable snmp access snmp-v1v2c&lt;br /&gt;
&lt;br /&gt;
Configurar informações básicas do dispositivo&lt;br /&gt;
 configure snmp sysName &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysLocation &#039;&#039;LOCALIZAÇÃO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysContact &#039;&#039;CONTATO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Habilitar SNMPv3&lt;br /&gt;
 enable snmp access snmpv3&lt;br /&gt;
&lt;br /&gt;
Adicionar usuário SNMP&lt;br /&gt;
 configure snmpv3 add user &#039;&#039;USUARIO&#039;&#039;&lt;br /&gt;
                          {authentication [md5 | sha] &#039;&#039;SENHA_DE_AUTENTICAÇAO&#039;&#039;}&lt;br /&gt;
                          {privacy {des | 3des | aes {128 | 192 | 256}} &#039;&#039;SENHA_PRIVADA&#039;&#039;}&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add group &#039;&#039;NOME_DO_GRUPO&#039;&#039; user &#039;&#039;USUARIO&#039;&#039; sec-model usm&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add access &#039;&#039;NOME_DO_GRUPO&#039;&#039; sec-model usm sec-level &lt;br /&gt;
                  [noauth | authnopriv | priv] {read-view read_view_name} {write-viewwrite_view_name} {notify-view notify_view_name}&lt;br /&gt;
&lt;br /&gt;
===Diagnóstico de Cabos de Rede===&lt;br /&gt;
Para realizar o diagnóstico do cabo de rede&lt;br /&gt;
 run diagnostics cable ports &amp;lt;port&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Analise os resultados:&lt;br /&gt;
 Ok: Sem falhas detectadas.&lt;br /&gt;
 Open: Cabo desconectado, com quebra física ou má terminação.&lt;br /&gt;
 Short: Curto-circuito nos pares do cabo.&lt;br /&gt;
 Hi Imp / Low Imp: Problemas de impedância ou conector defeituoso. &lt;br /&gt;
&lt;br /&gt;
Diagnóstico de Hardware Geral (Extended)&lt;br /&gt;
Se a suspeita for um problema físico no módulo de fibra ou porta em si:&lt;br /&gt;
 run diagnostics extended.&lt;br /&gt;
Nota: Este comando pode interromper o tráfego por até 15 minutos. &lt;br /&gt;
&lt;br /&gt;
Diagnóstico de Fibra Óptica&lt;br /&gt;
Como o run diagnostics cable não funciona em fibra, para validar conectividade óptica, utilize: &lt;br /&gt;
 show port &amp;lt;port&amp;gt; information detail (Verifique se há luz/sinal e erros de CRC).&lt;br /&gt;
 show transceiver (Verifique a potência de recepção/transmissão - Tx/Rx power). &lt;br /&gt;
&lt;br /&gt;
Dica: O uso desse comando pode impactar o tráfego nas portas testadas temporariamente&lt;br /&gt;
&lt;br /&gt;
Para informações de diagnóstico detalhadas para transceivers ópticos, incluindo fabricante, serial, presença de sinal e status de falha de transmissão.&lt;br /&gt;
 debug hal show optic-info port-list 1:30&lt;br /&gt;
Analise do resultado:&lt;br /&gt;
 Port                       1:30&lt;br /&gt;
 SFP or SFP+ or SFP28:      SFP+&lt;br /&gt;
 Signal:                    present&lt;br /&gt;
 TX Fault:                  no&lt;br /&gt;
 Vendor:                    FORMERICAOE&lt;br /&gt;
 oui:                       00-00-00&lt;br /&gt;
 Part Number:               TAS-A1NB1-FAHM&lt;br /&gt;
 Serial Number:             23088-92224&lt;br /&gt;
 Manufacture Date:          230559&lt;br /&gt;
 Revision:&lt;br /&gt;
 SFP/SFP-DD/SFP+/SFP28 Type:SFP/SFP+/SFP28&lt;br /&gt;
 Connector:                 LC(7)&lt;br /&gt;
 Type:                      LR&lt;br /&gt;
 Supported:                 yes&lt;br /&gt;
 Wavelength:                1310&lt;br /&gt;
 Options[0]:                0x00&lt;br /&gt;
 Options[1]:                0x1a&lt;br /&gt;
 GBIC supports DDMI.  MonitorType: 68&lt;br /&gt;
&lt;br /&gt;
===Desinstalar licenças de avaliação===&lt;br /&gt;
Siga o processo descrito em: https://extreme-networks.my.site.com/ExtrArticleDetail?an=000092952&lt;br /&gt;
&lt;br /&gt;
== Segurança ==&lt;br /&gt;
&lt;br /&gt;
=== Habilitar Logs ===&lt;br /&gt;
 enable log target session&lt;br /&gt;
&lt;br /&gt;
 configure syslog add [ipaddress {udp-port {udp_port}} | ipPort | ipaddress tls_port {tls_port}] {vr vr_name} [local0...local7]&lt;br /&gt;
&lt;br /&gt;
 enable syslog&lt;br /&gt;
&lt;br /&gt;
==== Registrar alterações no Log ====&lt;br /&gt;
&lt;br /&gt;
Permite registrar em Log as mudanças de configuração, assim como quem realizou a modificação. Útil para fins de auditoria.&lt;br /&gt;
&lt;br /&gt;
  enable cli config-logging&lt;br /&gt;
&lt;br /&gt;
=== Habilitar Port-Security/MAC Locking ===&lt;br /&gt;
&lt;br /&gt;
MAC Locking, ou bloqueio de MAC, é uma funcionalidade que permite a um switch aprender e armazenar os endereços MAC dos dispositivos conectados a suas portas. Uma vez que um endereço MAC é aprendido, o switch pode bloquear a porta para novos dispositivos, impedindo conexões não autorizadas.&lt;br /&gt;
 configure mac-locking ports &amp;lt;num_porta&amp;gt; first-arrival limit-learning &amp;lt;limite_de_MACs_na_porta&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== DHCP/BOOTP Relay ===&lt;br /&gt;
&lt;br /&gt;
 enable bootprelay {{vlan} vlan_name | {{vr} vr_name} | all [{vr} vr_name]}&lt;br /&gt;
&lt;br /&gt;
 configure bootprelay {vlan &#039;&#039;NOME_DA_VLAN_DO_DHCP_SERVER&#039;&#039;} add &#039;&#039;IP_DO_DHCP&#039;&#039; {vr vrid}&lt;br /&gt;
&lt;br /&gt;
Verificar as configurações de DHCP/BootRelay&lt;br /&gt;
&lt;br /&gt;
 show bootprelay configuration&lt;br /&gt;
&lt;br /&gt;
 show configuration nettools&lt;br /&gt;
&lt;br /&gt;
=== DHCP Snooping ===&lt;br /&gt;
&lt;br /&gt;
 enable ip-security dhcp-snooping vlan &#039;&#039;ID_DA_VLAN&#039;&#039; port [&#039;&#039;all&#039;&#039; | &#039;&#039;PORTA(S)&#039;&#039;] violation-action none&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Configure trusted ports (uplink port for DHCP Server)&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 configure trusted-ports &#039;&#039;PORTAS_DE_UPLINK&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
 configure trusted-servers vlan &#039;&#039;ID_DA_VLAN_DO_DHCP_SERVER&#039;&#039; add server &#039;&#039;IP_DO_DHCP&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
=== Como Criar ACLs ===&lt;br /&gt;
&lt;br /&gt;
[https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html]&lt;br /&gt;
&lt;br /&gt;
=== Netlogin ===&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000080274 https://extremeportal.force.com/ExtrArticleDetail?an=000080274]&lt;br /&gt;
&lt;br /&gt;
[https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402 https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402 https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin]&lt;br /&gt;
&lt;br /&gt;
[https://github.com/dwinurhadia/freeradius-macauth https://github.com/dwinurhadia/freeradius-macauth]&lt;br /&gt;
&lt;br /&gt;
[https://wiki.freeradius.org/guide/Mac-Auth https://wiki.freeradius.org/guide/Mac-Auth]&lt;br /&gt;
&lt;br /&gt;
=== Configurando o MAC-BASED VLAN ===&lt;br /&gt;
1. Primeiro deve-se criar a VLAN temporária que o netlogin irá utilizar para &amp;quot;conversar com o Radius&amp;quot; e, também, a VLAN que será utilizada para atribuir IPs para os computadores:&lt;br /&gt;
&lt;br /&gt;
  create vlan &amp;quot;NET_LOGIN&amp;quot;&lt;br /&gt;
  create vlan &amp;quot;REDE_187&amp;quot;&lt;br /&gt;
  configure vlan REDE_187 tag 187&lt;br /&gt;
  configure REDE_187 add ports 24 tagged&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
2. Configurar a autenticação das portas para o netlogin:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin vlan NET_LOGIN&lt;br /&gt;
  enable netlogin dot1x mac&lt;br /&gt;
  configure netlogin mac authentication database-order radius&lt;br /&gt;
  enable netlogin ports 1-23 mac&lt;br /&gt;
  configure netlogin ports 1-23 mode port-based-vlans&lt;br /&gt;
  configure netlogin ports 1-23 no-restart&lt;br /&gt;
  configure netlogin add mac-list ff:ff:ff:ff:ff:ff 48&lt;br /&gt;
&lt;br /&gt;
Obs: o mac-list informado refere-se ao broadcast do MAC address e o valor &amp;quot;48&amp;quot; ao tamanho em bits&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
3. Configurar a autenticação do Radius:&lt;br /&gt;
&lt;br /&gt;
  configure radius mgmt-access primary server 200.145.x.y 1812 client-ip 172.31.x.y vr VR-Default&lt;br /&gt;
  configure radius mgmt-access primary shared-secret encrypted &amp;quot;#$8VnrPisKgrhPOCh2WEepV==&amp;quot;&lt;br /&gt;
  configure radius netlogin primary server 200.145.x.y 1812 client-ip 172.31.x.y vr VR-Default&lt;br /&gt;
  configure radius netlogin primary shared-secret encrypted &amp;quot;#$kyGEk8PK4BbzEV+WJdapp16A==&amp;quot;&lt;br /&gt;
  enable radius&lt;br /&gt;
  enable radius mgmt-access&lt;br /&gt;
  enable radius netlogin&lt;br /&gt;
&lt;br /&gt;
Obs: o endereço &amp;quot;primary server&amp;quot; é o servidor do radius, a porta &amp;quot;1812&amp;quot; é a porta padrão do Authentication. A shared-secret é gerada com o comando &#039;&#039;configure radius mgmt-access/netlogin primary shared-secret&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
4. Quando não há conexão disponível com o PFSense irá direcionar para a VLAN especificada, ideal é uma VLAN com acesso restrito:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin authentication failure vlan VLAN_restrita ports 1-23&lt;br /&gt;
  configure netlogin authentication service-unavailable vlan VLAN_restrita ports 1-23&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
5. Configuracao para reautenticacao do mac em segundos:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin mac ports all timers reauth-period 60&lt;br /&gt;
  configure netlogin mac ports all timers reauthentication on&lt;br /&gt;
&lt;br /&gt;
Após inserir esta opção, não é possível tirar, apenas desabilitar:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin mac ports 1-23 timers reauth-period 3600 reauthentication off&lt;br /&gt;
  configure netlogin mac timers reauth-period 0&lt;br /&gt;
  configure netlogin session-timeout mac 0&lt;br /&gt;
&lt;br /&gt;
6. Para retirar a configuração do NETLOGIN de alguma porta:&lt;br /&gt;
&lt;br /&gt;
  disable netlogin ports &amp;lt;portas&amp;gt; mac&lt;br /&gt;
&lt;br /&gt;
=== Configurando PFSense ===&lt;br /&gt;
1. No FreeRADIUS, na opção Users inserir as informações de conexão para o computador (MAC-Address, senha), além deste usuário, também é necessário criar o usuário de conexão da switch com a senha:&lt;br /&gt;
&lt;br /&gt;
2. No campo Additional RADIUS Attributes (REPLY-ITEM) inserir o comando &amp;quot;Extreme-Netlogin-Extended-VLAN = U187&amp;quot;, onde a letra U é para representar que esta é a VLAN do usuário e o número é a tag da VLAN:&lt;br /&gt;
&lt;br /&gt;
3. Em NAS/Clients inserir o endereço IP do SiteEngine (186.217.0.16) em Client IP Address, inserir a senha da switch em Client Shared Secret e no campo NAS Login informar o nome de usuário para conexão da switch.&lt;br /&gt;
&lt;br /&gt;
4. Na opção Interfaces inserir as informações de Authentication, Accounting e Status (IP e Porta Padrão)&lt;br /&gt;
&lt;br /&gt;
=== ELRP e STP ===&lt;br /&gt;
&lt;br /&gt;
Extreme Loop Recovery Protocol (ELRP) é um protocolo proprietário que detecta loops de rede na Camada 2. O ELRP envia uma PDU especial pela VLAN e detecta um loop se o remetente switch recebe a mesma PDU de volta&lt;br /&gt;
&lt;br /&gt;
1) Sugestão: Criar uma VLAN para aplicar o ELRP e STP. Ela não precisa existir na rede:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
create vlan STPDOMAIN tag 4000&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
2) Ativando o ELRP:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
enable elrp-client&lt;br /&gt;
configure elrp-client periodic vlan STPDOMAIN ports all disable-port duration 60&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
3) Configurando o stpd s0:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
disable stpd s0&lt;br /&gt;
configure stpd s0 mode dot1w&lt;br /&gt;
enable stpd s0 rapid-root-failover&lt;br /&gt;
enable stpd s0 auto-bind vlan STPDOMAIN&lt;br /&gt;
&lt;br /&gt;
configure stpd s0 ports link-type edge 1:1-24&lt;br /&gt;
configure stpd s0 ports edge-safeguard enable 1:1-24 recovery-timeout 60&lt;br /&gt;
configure stpd s0 ports bpdu-restrict enable 1:1-24 recovery-timeout 60&lt;br /&gt;
configure stpd s0 ports restricted-tcn on 1:1-24&lt;br /&gt;
&lt;br /&gt;
configure stpd s0 tag 4000&lt;br /&gt;
enable stpd s0&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* link-type edge: Define o tipo da porta [[auto | broadcast | point-to-point] port_list | edge port_list {edge-safeguard [enable | disable] {bpdu-restrict} {recovery-timeout seconds}}]&lt;br /&gt;
* edge-safeguard: - Previne LOOP no STPD&lt;br /&gt;
* bpdu-restrict: Impede que transmitido pacote BPDU nas portas (ligar outra Switch)&lt;br /&gt;
* restricted-tcn: Impede a propagação de BPDUs TCN na porta&lt;br /&gt;
&amp;lt;b&amp;gt;Se for realizar uplink via UTP, é necessário alterar as configurações acima para evitar que a porta seja desativada&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Para desabilitar BPDU nas portas:&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports link-type auto &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports edge-safeguard disable &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports bpdu-restrict disable &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== Bloqueio de endereços mac-ddress ===&lt;br /&gt;
&lt;br /&gt;
1. Pode ser utilizado o comando a seguir para criar uma lista BLACKHOLE, quando o bloqueio é específico dentro de uma VLAN:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
create fdb 01:00:5E:00:E0:00 vlan vlan_name [ports port_list | blackhole]&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
Para excluir utilize:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
delete fdb [all | mac_address [vlan vlan_name ] &lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
2. Caso o bloqueio desejado seja para qualquer VLAN existente, pode-se criar uma regra ACL:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
entry block_MAC {&lt;br /&gt;
      if { ethernet-source-address 01:00:5E:00:E0:00; } then { deny; }&lt;br /&gt;
}&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;/div&gt;</summary>
		<author><name>Guilherme.marques</name></author>
	</entry>
	<entry>
		<id>https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=1087</id>
		<title>Switch Extreme</title>
		<link rel="alternate" type="text/html" href="https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=1087"/>
		<updated>2026-06-03T19:02:27Z</updated>

		<summary type="html">&lt;p&gt;Guilherme.marques: Guilherme.marques moveu Restrito:Switch Extreme para seu redirecionamento Switch Extreme: teste&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Extreme]]&lt;br /&gt;
&lt;br /&gt;
== Configuração Serial ==&lt;br /&gt;
&lt;br /&gt;
 Speed Bus: &#039;&#039;&#039;115200&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Comandos ==&lt;br /&gt;
&lt;br /&gt;
===Configurações Básicas===&lt;br /&gt;
 &lt;br /&gt;
Apaga todas as configurações do Switch&lt;br /&gt;
 unconfigure switch all&lt;br /&gt;
&lt;br /&gt;
Habilitar SSH&lt;br /&gt;
 enable ssh2&lt;br /&gt;
&lt;br /&gt;
Desabilitar Telnet&lt;br /&gt;
 disable telnet&lt;br /&gt;
&lt;br /&gt;
Remover todas as portas da VLAN default&lt;br /&gt;
&lt;br /&gt;
 configure vlan Default delete ports all&lt;br /&gt;
&lt;br /&gt;
Remover uma VLAN especifica&lt;br /&gt;
 &lt;br /&gt;
 configure vlan &amp;lt;vlan_name&amp;gt; delete ports all&lt;br /&gt;
&lt;br /&gt;
 delete vlan &amp;lt;vlan_name&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Configurar o nome do Switch&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysname &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Salvar configurações&lt;br /&gt;
&lt;br /&gt;
 save&lt;br /&gt;
&lt;br /&gt;
==== SNTP ====&lt;br /&gt;
&lt;br /&gt;
 enable sntp-client &lt;br /&gt;
&lt;br /&gt;
 configure sntp-client primary &#039;&#039;IP_DO_SERVIDOR_NTP&#039;&#039; vr VR-Default&lt;br /&gt;
&lt;br /&gt;
 configure sntp-client update-interval 30&lt;br /&gt;
&lt;br /&gt;
Definir TimeZone do Brasil&lt;br /&gt;
&lt;br /&gt;
 configure timezone name BRTZ -180 noautodst&lt;br /&gt;
&lt;br /&gt;
Horário de verão&lt;br /&gt;
&lt;br /&gt;
 configure timezone name BRTZ -180 autodst name DST 0 begins every third sunday october at 0 0 ends every third sunday february at 0 0&lt;br /&gt;
&lt;br /&gt;
=== Configuração de Portas ===&lt;br /&gt;
&lt;br /&gt;
Ativar porta&lt;br /&gt;
&lt;br /&gt;
 enable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Desativar uma porta&lt;br /&gt;
&lt;br /&gt;
 disable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Colocar um rótulo em uma porta do switch&lt;br /&gt;
 configure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; display-string &#039;&#039;NOME_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Informações detalhadas de porta&lt;br /&gt;
&lt;br /&gt;
  show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; information detail&lt;br /&gt;
&lt;br /&gt;
Retirar um rótulo em uma porta do switch&lt;br /&gt;
 unconfigure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; display-string&lt;br /&gt;
&lt;br /&gt;
Retirar uma descrição em uma porta do switch&lt;br /&gt;
 unconfigure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; description-string&lt;br /&gt;
&lt;br /&gt;
=== Nodealias ===&lt;br /&gt;
Utilize o comando para ter informações mais completas de uso das portas (mac, ip, vlan, etc). Não colocar as portas de link, para melhor localizar o equipamento dentro da topologia utilizada.&lt;br /&gt;
Também o número de maxentries é 8192 para todo o dispositivo, ou seja é o número máximo que é armazenado por slot, por exemplo, para um stack com 7 switches o valor para maxentries deveria ficar em torno de &#039;48&#039;.&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 configure nodealias ports [port_list | all] maxentries entries&lt;br /&gt;
 enable nodealias port [port_list | all]&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 show nodealias port all&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 show nodealias ip &#039;&#039;ENDEREÇO_IP&#039;&#039;&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
Para desfazer as configurações utilize:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
clear nodealias { ports [port_list | all] | alias-id alias_id }&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== VLANS ===&lt;br /&gt;
Criar VLAN&lt;br /&gt;
&lt;br /&gt;
 create vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; tag &#039;&#039;NUMERO_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Adicionar porta(s) a uma VLAN&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; add port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; [tagged | untagged]&lt;br /&gt;
&lt;br /&gt;
Verificar qual VLAN uma(s) porta pertence&lt;br /&gt;
&lt;br /&gt;
 show vlan port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; vlan&lt;br /&gt;
&lt;br /&gt;
=== Configurações de Rede / IP ===&lt;br /&gt;
Configurar um IP em uma VLAN do Switch&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; ipaddress &#039;&#039;ENDEREÇO_IP/MASCARA_CIDR&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Configurar gateway padrão&lt;br /&gt;
 configure iproute add default &#039;&#039;IP_DO_GATEWAY&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Verificar rotas&lt;br /&gt;
&lt;br /&gt;
 show iproute&lt;br /&gt;
&lt;br /&gt;
Configurar o servidor DNS&lt;br /&gt;
 configure dns-client add name-server &#039;&#039;IP_DO_DNS&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== DHCP Server no Switch ===&lt;br /&gt;
&lt;br /&gt;
Configurar um IP em uma VLAN do Switch. Será o gateway do DHCP.&lt;br /&gt;
&lt;br /&gt;
Habilitar o servidor DHCP e defina o intervalo de endereços IP que o servidor DHCP irá distribuir.&lt;br /&gt;
 enable dhcp vlan &amp;lt;nome&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-address-range &amp;lt;ip_inicial&amp;gt; - &amp;lt;ip_final&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-lease-timer &amp;lt;tempo_lease&amp;gt;&lt;br /&gt;
Configurar Opções Adicionais de DHCP&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-options default-gateway &amp;lt;ip_gateway&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-options dns-server primary &amp;lt;ip_dns&amp;gt;&lt;br /&gt;
 enable dhcp ports &amp;lt;num_porta&amp;gt; vlan &amp;lt;nome&amp;gt; &lt;br /&gt;
Para consultar a tabela de alocação:&lt;br /&gt;
&lt;br /&gt;
 show vlan &amp;lt;nome&amp;gt; dhcp-address-allocation&lt;br /&gt;
&lt;br /&gt;
===Comandos (SHOW) para verificações de configurações ===&lt;br /&gt;
 show accounts&lt;br /&gt;
&lt;br /&gt;
 show configuration&lt;br /&gt;
&lt;br /&gt;
 show version&lt;br /&gt;
&lt;br /&gt;
 show version images&lt;br /&gt;
&lt;br /&gt;
 show system&lt;br /&gt;
&lt;br /&gt;
 show switch&lt;br /&gt;
&lt;br /&gt;
 show switch management&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Verifica portas agregadas&lt;br /&gt;
 show sharing&lt;br /&gt;
&lt;br /&gt;
 show licenses&lt;br /&gt;
&lt;br /&gt;
 show time&lt;br /&gt;
&lt;br /&gt;
 show log&lt;br /&gt;
&lt;br /&gt;
 show vlan&lt;br /&gt;
&lt;br /&gt;
 show vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;PORTA&#039;&#039; no-refresh&lt;br /&gt;
&lt;br /&gt;
 show cli journal&lt;br /&gt;
&lt;br /&gt;
 history&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Verificar se o equipamento esta sendo gerenciado pela Cloud&lt;br /&gt;
 show iqagent&lt;br /&gt;
&lt;br /&gt;
 show iqagent discovery detail&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Mostra tabela ARP&lt;br /&gt;
 show iparp&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Mostra informações de status (up/down) das portas&lt;br /&gt;
 show ports information detail | include Port:|Link\sState:|Link\sUps:|Link\sDowns&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Monitorar o tráfego de entrada e saída de uma VLAN&lt;br /&gt;
Habilitar o monitoramento na VLAN desejada:&lt;br /&gt;
 configure ports all monitor vlan &amp;lt;vlan_name&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Ver as informações da VLAN:&lt;br /&gt;
 show vlan statistics no-refresh&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==== Tabelas MAC / VLAN / Portas ====&lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;ENDERECO_MAC&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Para obter informações de mais do que um endereço, coloque os mac&#039;s entre aspas duplas, separados por um pipe &#039;|&#039;, por exemplo:&lt;br /&gt;
&lt;br /&gt;
 show fdb | include &amp;quot;ENDERECO_MAC1|ENDERECO_MAC2|ENDERECO_MAC3|....&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;PORTA_DO_SWITCH&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 show fdb vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== Empilhamento ===&lt;br /&gt;
&lt;br /&gt;
Para configurar uma nova pilha:&lt;br /&gt;
&lt;br /&gt;
1- Conecte fisicamente os nós usando as portas de empilhamento.&lt;br /&gt;
&lt;br /&gt;
2- Ligue os nós.&lt;br /&gt;
&lt;br /&gt;
3- Para cada switch no qual as portas de stacking ainda não estão ativadas, emita o comando:&lt;br /&gt;
&lt;br /&gt;
 enable stacking-support&lt;br /&gt;
&lt;br /&gt;
4- Verifique se todos os switches têm o mesmo protocolo de empilhamento e suporte&lt;br /&gt;
de empilhamento configurados.&lt;br /&gt;
&lt;br /&gt;
5- Efetue login em qualquer um dos nós através da porta do console, de preferência&lt;br /&gt;
aquela que você deseja usar como mestre. Se você planeja usar o Easy Setup, efetue&lt;br /&gt;
login no nó Master pretendido. Se a pilha for uma nova pilha, os parâmetros padrão&lt;br /&gt;
estão em vigor.&lt;br /&gt;
&lt;br /&gt;
6- Para verificar a pilha digite:&lt;br /&gt;
 show stacking&lt;br /&gt;
O comando “show stacking” exibe todos os nós na pilha. Todos os nós estão em um estado desativado e todos os nós aparecem como nós principais.&lt;br /&gt;
&lt;br /&gt;
7- Digite no switch Master.&lt;br /&gt;
 enable stacking&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Nota:&#039;&#039;&#039; &#039;&#039;Todos os switches devem ter o suporte de empilhamento ativado, mas&lt;br /&gt;
desabilitado, antes de executar o Easy Setup.&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
8- Este comando apresenta a opção de usar o procedimento de instalação fácil. Digite&lt;br /&gt;
 configure stacking easy-setup&lt;br /&gt;
&lt;br /&gt;
9- Reinicie o stack e digite:&lt;br /&gt;
 reboot stack-topology&lt;br /&gt;
&lt;br /&gt;
A configuração é definida como&lt;br /&gt;
valores padrão ao entrar no modo de empilhamento, portanto, todas as informações de&lt;br /&gt;
configuração inseridas anteriormente (exceto os parâmetros de empilhamento com&lt;br /&gt;
base na NVRAM, a imagem selecionada e as informações da conta à prova de falhas) não&lt;br /&gt;
estão disponíveis.&lt;br /&gt;
10- Faça login no nó Master pretendido e verifique os comandos do tipo de pilha &lt;br /&gt;
 show stacking&lt;br /&gt;
 show slot &lt;br /&gt;
 show stacking configuration&lt;br /&gt;
&lt;br /&gt;
11- Se a configuração da pilha for bem-sucedida:&lt;br /&gt;
- Todos os nós são visíveis na pilha.&lt;br /&gt;
- Todos os nós passam para o estado ativo.&lt;br /&gt;
- Algum tempo depois que os nós se tornam ativos, cada nó está presente no slot configurado.&lt;br /&gt;
- Depois que as funções são finalizadas, você pode ver um nó Master e um nó backup.&lt;br /&gt;
12- Verifique se o nó Master é o que você pretendia ser o Master.&lt;br /&gt;
&lt;br /&gt;
=== PoE ===&lt;br /&gt;
&lt;br /&gt;
PoE vem habilitado por padrão nos switches Extreme, para desabilitar, utilize os comandos:&lt;br /&gt;
&lt;br /&gt;
 disable inline-power&lt;br /&gt;
&lt;br /&gt;
 disable inline-power slot &amp;lt;slot&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 disable inline-power ports &amp;lt;port&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Verificando estatísticas da porta visando identificar problemas&lt;br /&gt;
&lt;br /&gt;
 show inline-power&lt;br /&gt;
 show inline-power configuration ports&lt;br /&gt;
 show inline-power info detail ports&lt;br /&gt;
 show inline-power stats ports&lt;br /&gt;
&lt;br /&gt;
O comando de &amp;quot;stats&amp;quot; possibilita identificar a classe do PD (Powered Device) definida em IEEE 802.3 (802.3af, 802.3at, 802.3bt) e associadas com níveis de potência específicas :&lt;br /&gt;
&lt;br /&gt;
    Class 0: Default for Type 1 PDs (802.3af), up to 13W.&lt;br /&gt;
    Class 1: Type 1 PD (802.3af), up to 3.84W.&lt;br /&gt;
    Class 2: Type 1 PD (802.3af), up to 6.49W.&lt;br /&gt;
    Class 3: Type 1 PD (802.3af), up to 13W.&lt;br /&gt;
    Class 4: Type 2 PD (802.3at PoE+), up to 25.5W.&lt;br /&gt;
    Class 5: Type 3 PD (802.3bt), up to 40W.&lt;br /&gt;
    Class 6: Type 3 PD (802.3bt), up to 51W.&lt;br /&gt;
    Class 7: Type 4 PD (802.3bt), up to 62W.&lt;br /&gt;
    Class 8: Type 4 PD (802.3bt), up to 71.3W.&lt;br /&gt;
&lt;br /&gt;
Por exemplo:&lt;br /&gt;
 # show inline-power stats ports 1:1-6&lt;br /&gt;
&lt;br /&gt;
                                STATISTICS COUNTERS&lt;br /&gt;
 Port     State         Class     Absent  InvSig   Denied    OverCurrent   Short&lt;br /&gt;
 1:1      delivering    class4        0       0       6          0             0&lt;br /&gt;
 1:2      searching     ------      113       0     118          0             0&lt;br /&gt;
 1:3      searching     ------        0     234       0          0             0&lt;br /&gt;
 1:4      searching     ------        0     226       0          0             0&lt;br /&gt;
 1:5      delivering    class2        1       5       7          0             0&lt;br /&gt;
 1:6      delivering    class2        0       0       6          0             0&lt;br /&gt;
&lt;br /&gt;
As colunas representam:&lt;br /&gt;
&lt;br /&gt;
#Absent: Exibe o número de vezes que a porta foi desconectada.&lt;br /&gt;
#InvSig: Exibe o número de vezes que a porta tinha uma assinatura inválida.&lt;br /&gt;
#Denied: Exibe o número de vezes que a porta foi negada.&lt;br /&gt;
#Over-current: Exibe o número de vezes que a porta entrou em um estado de sobrecorrente.&lt;br /&gt;
#Short: Exibe o número de vezes que a porta entrou no estado de corrente.&lt;br /&gt;
&lt;br /&gt;
(Fonte: https://documentation.extremenetworks.com/switchengine_commands_32.2/downloads/SwitchEngine_Command_Reference_32.2.pdf)&lt;br /&gt;
&lt;br /&gt;
===SNMP===&lt;br /&gt;
Desabilitar os protocolos SNMPv1/v2c&lt;br /&gt;
 disable snmp access snmp-v1v2c&lt;br /&gt;
&lt;br /&gt;
Configurar informações básicas do dispositivo&lt;br /&gt;
 configure snmp sysName &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysLocation &#039;&#039;LOCALIZAÇÃO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysContact &#039;&#039;CONTATO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Habilitar SNMPv3&lt;br /&gt;
 enable snmp access snmpv3&lt;br /&gt;
&lt;br /&gt;
Adicionar usuário SNMP&lt;br /&gt;
 configure snmpv3 add user &#039;&#039;USUARIO&#039;&#039;&lt;br /&gt;
                          {authentication [md5 | sha] &#039;&#039;SENHA_DE_AUTENTICAÇAO&#039;&#039;}&lt;br /&gt;
                          {privacy {des | 3des | aes {128 | 192 | 256}} &#039;&#039;SENHA_PRIVADA&#039;&#039;}&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add group &#039;&#039;NOME_DO_GRUPO&#039;&#039; user &#039;&#039;USUARIO&#039;&#039; sec-model usm&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add access &#039;&#039;NOME_DO_GRUPO&#039;&#039; sec-model usm sec-level &lt;br /&gt;
                  [noauth | authnopriv | priv] {read-view read_view_name} {write-viewwrite_view_name} {notify-view notify_view_name}&lt;br /&gt;
&lt;br /&gt;
===Diagnóstico de Cabos de Rede===&lt;br /&gt;
Para realizar o diagnóstico do cabo de rede&lt;br /&gt;
 run diagnostics cable ports &amp;lt;port&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Analise os resultados:&lt;br /&gt;
 Ok: Sem falhas detectadas.&lt;br /&gt;
 Open: Cabo desconectado, com quebra física ou má terminação.&lt;br /&gt;
 Short: Curto-circuito nos pares do cabo.&lt;br /&gt;
 Hi Imp / Low Imp: Problemas de impedância ou conector defeituoso. &lt;br /&gt;
&lt;br /&gt;
Diagnóstico de Hardware Geral (Extended)&lt;br /&gt;
Se a suspeita for um problema físico no módulo de fibra ou porta em si:&lt;br /&gt;
 run diagnostics extended.&lt;br /&gt;
Nota: Este comando pode interromper o tráfego por até 15 minutos. &lt;br /&gt;
&lt;br /&gt;
Diagnóstico de Fibra Óptica&lt;br /&gt;
Como o run diagnostics cable não funciona em fibra, para validar conectividade óptica, utilize: &lt;br /&gt;
 show port &amp;lt;port&amp;gt; information detail (Verifique se há luz/sinal e erros de CRC).&lt;br /&gt;
 show transceiver (Verifique a potência de recepção/transmissão - Tx/Rx power). &lt;br /&gt;
&lt;br /&gt;
Dica: O uso desse comando pode impactar o tráfego nas portas testadas temporariamente&lt;br /&gt;
&lt;br /&gt;
Para informações de diagnóstico detalhadas para transceivers ópticos, incluindo fabricante, serial, presença de sinal e status de falha de transmissão.&lt;br /&gt;
 debug hal show optic-info port-list 1:30&lt;br /&gt;
Analise do resultado:&lt;br /&gt;
 Port                       1:30&lt;br /&gt;
 SFP or SFP+ or SFP28:      SFP+&lt;br /&gt;
 Signal:                    present&lt;br /&gt;
 TX Fault:                  no&lt;br /&gt;
 Vendor:                    FORMERICAOE&lt;br /&gt;
 oui:                       00-00-00&lt;br /&gt;
 Part Number:               TAS-A1NB1-FAHM&lt;br /&gt;
 Serial Number:             23088-92224&lt;br /&gt;
 Manufacture Date:          230559&lt;br /&gt;
 Revision:&lt;br /&gt;
 SFP/SFP-DD/SFP+/SFP28 Type:SFP/SFP+/SFP28&lt;br /&gt;
 Connector:                 LC(7)&lt;br /&gt;
 Type:                      LR&lt;br /&gt;
 Supported:                 yes&lt;br /&gt;
 Wavelength:                1310&lt;br /&gt;
 Options[0]:                0x00&lt;br /&gt;
 Options[1]:                0x1a&lt;br /&gt;
 GBIC supports DDMI.  MonitorType: 68&lt;br /&gt;
&lt;br /&gt;
===Desinstalar licenças de avaliação===&lt;br /&gt;
Siga o processo descrito em: https://extreme-networks.my.site.com/ExtrArticleDetail?an=000092952&lt;br /&gt;
&lt;br /&gt;
== Segurança ==&lt;br /&gt;
&lt;br /&gt;
=== Habilitar Logs ===&lt;br /&gt;
 enable log target session&lt;br /&gt;
&lt;br /&gt;
 configure syslog add [ipaddress {udp-port {udp_port}} | ipPort | ipaddress tls_port {tls_port}] {vr vr_name} [local0...local7]&lt;br /&gt;
&lt;br /&gt;
 enable syslog&lt;br /&gt;
&lt;br /&gt;
==== Registrar alterações no Log ====&lt;br /&gt;
&lt;br /&gt;
Permite registrar em Log as mudanças de configuração, assim como quem realizou a modificação. Útil para fins de auditoria.&lt;br /&gt;
&lt;br /&gt;
  enable cli config-logging&lt;br /&gt;
&lt;br /&gt;
=== Habilitar Port-Security/MAC Locking ===&lt;br /&gt;
&lt;br /&gt;
MAC Locking, ou bloqueio de MAC, é uma funcionalidade que permite a um switch aprender e armazenar os endereços MAC dos dispositivos conectados a suas portas. Uma vez que um endereço MAC é aprendido, o switch pode bloquear a porta para novos dispositivos, impedindo conexões não autorizadas.&lt;br /&gt;
 configure mac-locking ports &amp;lt;num_porta&amp;gt; first-arrival limit-learning &amp;lt;limite_de_MACs_na_porta&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== DHCP/BOOTP Relay ===&lt;br /&gt;
&lt;br /&gt;
 enable bootprelay {{vlan} vlan_name | {{vr} vr_name} | all [{vr} vr_name]}&lt;br /&gt;
&lt;br /&gt;
 configure bootprelay {vlan &#039;&#039;NOME_DA_VLAN_DO_DHCP_SERVER&#039;&#039;} add &#039;&#039;IP_DO_DHCP&#039;&#039; {vr vrid}&lt;br /&gt;
&lt;br /&gt;
Verificar as configurações de DHCP/BootRelay&lt;br /&gt;
&lt;br /&gt;
 show bootprelay configuration&lt;br /&gt;
&lt;br /&gt;
 show configuration nettools&lt;br /&gt;
&lt;br /&gt;
=== DHCP Snooping ===&lt;br /&gt;
&lt;br /&gt;
 enable ip-security dhcp-snooping vlan &#039;&#039;ID_DA_VLAN&#039;&#039; port [&#039;&#039;all&#039;&#039; | &#039;&#039;PORTA(S)&#039;&#039;] violation-action none&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Configure trusted ports (uplink port for DHCP Server)&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 configure trusted-ports &#039;&#039;PORTAS_DE_UPLINK&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
 configure trusted-servers vlan &#039;&#039;ID_DA_VLAN_DO_DHCP_SERVER&#039;&#039; add server &#039;&#039;IP_DO_DHCP&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
=== Como Criar ACLs ===&lt;br /&gt;
&lt;br /&gt;
[https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html]&lt;br /&gt;
&lt;br /&gt;
=== Netlogin ===&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000080274 https://extremeportal.force.com/ExtrArticleDetail?an=000080274]&lt;br /&gt;
&lt;br /&gt;
[https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402 https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402 https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin]&lt;br /&gt;
&lt;br /&gt;
[https://github.com/dwinurhadia/freeradius-macauth https://github.com/dwinurhadia/freeradius-macauth]&lt;br /&gt;
&lt;br /&gt;
[https://wiki.freeradius.org/guide/Mac-Auth https://wiki.freeradius.org/guide/Mac-Auth]&lt;br /&gt;
&lt;br /&gt;
=== Configurando o MAC-BASED VLAN ===&lt;br /&gt;
1. Primeiro deve-se criar a VLAN temporária que o netlogin irá utilizar para &amp;quot;conversar com o Radius&amp;quot; e, também, a VLAN que será utilizada para atribuir IPs para os computadores:&lt;br /&gt;
&lt;br /&gt;
  create vlan &amp;quot;NET_LOGIN&amp;quot;&lt;br /&gt;
  create vlan &amp;quot;REDE_187&amp;quot;&lt;br /&gt;
  configure vlan REDE_187 tag 187&lt;br /&gt;
  configure REDE_187 add ports 24 tagged&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
2. Configurar a autenticação das portas para o netlogin:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin vlan NET_LOGIN&lt;br /&gt;
  enable netlogin dot1x mac&lt;br /&gt;
  configure netlogin mac authentication database-order radius&lt;br /&gt;
  enable netlogin ports 1-23 mac&lt;br /&gt;
  configure netlogin ports 1-23 mode port-based-vlans&lt;br /&gt;
  configure netlogin ports 1-23 no-restart&lt;br /&gt;
  configure netlogin add mac-list ff:ff:ff:ff:ff:ff 48&lt;br /&gt;
&lt;br /&gt;
Obs: o mac-list informado refere-se ao broadcast do MAC address e o valor &amp;quot;48&amp;quot; ao tamanho em bits&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
3. Configurar a autenticação do Radius:&lt;br /&gt;
&lt;br /&gt;
  configure radius mgmt-access primary server 200.145.x.y 1812 client-ip 172.31.x.y vr VR-Default&lt;br /&gt;
  configure radius mgmt-access primary shared-secret encrypted &amp;quot;#$8VnrPisKgrhPOCh2WEepV==&amp;quot;&lt;br /&gt;
  configure radius netlogin primary server 200.145.x.y 1812 client-ip 172.31.x.y vr VR-Default&lt;br /&gt;
  configure radius netlogin primary shared-secret encrypted &amp;quot;#$kyGEk8PK4BbzEV+WJdapp16A==&amp;quot;&lt;br /&gt;
  enable radius&lt;br /&gt;
  enable radius mgmt-access&lt;br /&gt;
  enable radius netlogin&lt;br /&gt;
&lt;br /&gt;
Obs: o endereço &amp;quot;primary server&amp;quot; é o servidor do radius, a porta &amp;quot;1812&amp;quot; é a porta padrão do Authentication. A shared-secret é gerada com o comando &#039;&#039;configure radius mgmt-access/netlogin primary shared-secret&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
4. Quando não há conexão disponível com o PFSense irá direcionar para a VLAN especificada, ideal é uma VLAN com acesso restrito:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin authentication failure vlan VLAN_restrita ports 1-23&lt;br /&gt;
  configure netlogin authentication service-unavailable vlan VLAN_restrita ports 1-23&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
5. Configuracao para reautenticacao do mac em segundos:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin mac ports all timers reauth-period 60&lt;br /&gt;
  configure netlogin mac ports all timers reauthentication on&lt;br /&gt;
&lt;br /&gt;
Após inserir esta opção, não é possível tirar, apenas desabilitar:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin mac ports 1-23 timers reauth-period 3600 reauthentication off&lt;br /&gt;
  configure netlogin mac timers reauth-period 0&lt;br /&gt;
  configure netlogin session-timeout mac 0&lt;br /&gt;
&lt;br /&gt;
6. Para retirar a configuração do NETLOGIN de alguma porta:&lt;br /&gt;
&lt;br /&gt;
  disable netlogin ports &amp;lt;portas&amp;gt; mac&lt;br /&gt;
&lt;br /&gt;
=== Configurando PFSense ===&lt;br /&gt;
1. No FreeRADIUS, na opção Users inserir as informações de conexão para o computador (MAC-Address, senha), além deste usuário, também é necessário criar o usuário de conexão da switch com a senha:&lt;br /&gt;
&lt;br /&gt;
2. No campo Additional RADIUS Attributes (REPLY-ITEM) inserir o comando &amp;quot;Extreme-Netlogin-Extended-VLAN = U187&amp;quot;, onde a letra U é para representar que esta é a VLAN do usuário e o número é a tag da VLAN:&lt;br /&gt;
&lt;br /&gt;
3. Em NAS/Clients inserir o endereço IP do SiteEngine (186.217.0.16) em Client IP Address, inserir a senha da switch em Client Shared Secret e no campo NAS Login informar o nome de usuário para conexão da switch.&lt;br /&gt;
&lt;br /&gt;
4. Na opção Interfaces inserir as informações de Authentication, Accounting e Status (IP e Porta Padrão)&lt;br /&gt;
&lt;br /&gt;
=== ELRP e STP ===&lt;br /&gt;
&lt;br /&gt;
Extreme Loop Recovery Protocol (ELRP) é um protocolo proprietário que detecta loops de rede na Camada 2. O ELRP envia uma PDU especial pela VLAN e detecta um loop se o remetente switch recebe a mesma PDU de volta&lt;br /&gt;
&lt;br /&gt;
1) Sugestão: Criar uma VLAN para aplicar o ELRP e STP. Ela não precisa existir na rede:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
create vlan STPDOMAIN tag 4000&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
2) Ativando o ELRP:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
enable elrp-client&lt;br /&gt;
configure elrp-client periodic vlan STPDOMAIN ports all disable-port duration 60&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
3) Configurando o stpd s0:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
disable stpd s0&lt;br /&gt;
configure stpd s0 mode dot1w&lt;br /&gt;
enable stpd s0 rapid-root-failover&lt;br /&gt;
enable stpd s0 auto-bind vlan STPDOMAIN&lt;br /&gt;
&lt;br /&gt;
configure stpd s0 ports link-type edge 1:1-24&lt;br /&gt;
configure stpd s0 ports edge-safeguard enable 1:1-24 recovery-timeout 60&lt;br /&gt;
configure stpd s0 ports bpdu-restrict enable 1:1-24 recovery-timeout 60&lt;br /&gt;
configure stpd s0 ports restricted-tcn on 1:1-24&lt;br /&gt;
&lt;br /&gt;
configure stpd s0 tag 4000&lt;br /&gt;
enable stpd s0&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* link-type edge: Define o tipo da porta [[auto | broadcast | point-to-point] port_list | edge port_list {edge-safeguard [enable | disable] {bpdu-restrict} {recovery-timeout seconds}}]&lt;br /&gt;
* edge-safeguard: - Previne LOOP no STPD&lt;br /&gt;
* bpdu-restrict: Impede que transmitido pacote BPDU nas portas (ligar outra Switch)&lt;br /&gt;
* restricted-tcn: Impede a propagação de BPDUs TCN na porta&lt;br /&gt;
&amp;lt;b&amp;gt;Se for realizar uplink via UTP, é necessário alterar as configurações acima para evitar que a porta seja desativada&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Para desabilitar BPDU nas portas:&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports link-type auto &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports edge-safeguard disable &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports bpdu-restrict disable &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== Bloqueio de endereços mac-ddress ===&lt;br /&gt;
&lt;br /&gt;
1. Pode ser utilizado o comando a seguir para criar uma lista BLACKHOLE, quando o bloqueio é específico dentro de uma VLAN:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
create fdb 01:00:5E:00:E0:00 vlan vlan_name [ports port_list | blackhole]&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
Para excluir utilize:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
delete fdb [all | mac_address [vlan vlan_name ] &lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
2. Caso o bloqueio desejado seja para qualquer VLAN existente, pode-se criar uma regra ACL:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
entry block_MAC {&lt;br /&gt;
      if { ethernet-source-address 01:00:5E:00:E0:00; } then { deny; }&lt;br /&gt;
}&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;/div&gt;</summary>
		<author><name>Guilherme.marques</name></author>
	</entry>
	<entry>
		<id>https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=1085</id>
		<title>Switch Extreme</title>
		<link rel="alternate" type="text/html" href="https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=1085"/>
		<updated>2026-06-03T18:59:18Z</updated>

		<summary type="html">&lt;p&gt;Guilherme.marques: Guilherme.marques moveu Switch Extreme para Restrito:Switch Extreme: Teste&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Extreme]]&lt;br /&gt;
&lt;br /&gt;
== Configuração Serial ==&lt;br /&gt;
&lt;br /&gt;
 Speed Bus: &#039;&#039;&#039;115200&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Comandos ==&lt;br /&gt;
&lt;br /&gt;
===Configurações Básicas===&lt;br /&gt;
 &lt;br /&gt;
Apaga todas as configurações do Switch&lt;br /&gt;
 unconfigure switch all&lt;br /&gt;
&lt;br /&gt;
Habilitar SSH&lt;br /&gt;
 enable ssh2&lt;br /&gt;
&lt;br /&gt;
Desabilitar Telnet&lt;br /&gt;
 disable telnet&lt;br /&gt;
&lt;br /&gt;
Remover todas as portas da VLAN default&lt;br /&gt;
&lt;br /&gt;
 configure vlan Default delete ports all&lt;br /&gt;
&lt;br /&gt;
Remover uma VLAN especifica&lt;br /&gt;
 &lt;br /&gt;
 configure vlan &amp;lt;vlan_name&amp;gt; delete ports all&lt;br /&gt;
&lt;br /&gt;
 delete vlan &amp;lt;vlan_name&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Configurar o nome do Switch&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysname &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Salvar configurações&lt;br /&gt;
&lt;br /&gt;
 save&lt;br /&gt;
&lt;br /&gt;
==== SNTP ====&lt;br /&gt;
&lt;br /&gt;
 enable sntp-client &lt;br /&gt;
&lt;br /&gt;
 configure sntp-client primary &#039;&#039;IP_DO_SERVIDOR_NTP&#039;&#039; vr VR-Default&lt;br /&gt;
&lt;br /&gt;
 configure sntp-client update-interval 30&lt;br /&gt;
&lt;br /&gt;
Definir TimeZone do Brasil&lt;br /&gt;
&lt;br /&gt;
 configure timezone name BRTZ -180 noautodst&lt;br /&gt;
&lt;br /&gt;
Horário de verão&lt;br /&gt;
&lt;br /&gt;
 configure timezone name BRTZ -180 autodst name DST 0 begins every third sunday october at 0 0 ends every third sunday february at 0 0&lt;br /&gt;
&lt;br /&gt;
=== Configuração de Portas ===&lt;br /&gt;
&lt;br /&gt;
Ativar porta&lt;br /&gt;
&lt;br /&gt;
 enable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Desativar uma porta&lt;br /&gt;
&lt;br /&gt;
 disable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Colocar um rótulo em uma porta do switch&lt;br /&gt;
 configure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; display-string &#039;&#039;NOME_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Informações detalhadas de porta&lt;br /&gt;
&lt;br /&gt;
  show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; information detail&lt;br /&gt;
&lt;br /&gt;
Retirar um rótulo em uma porta do switch&lt;br /&gt;
 unconfigure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; display-string&lt;br /&gt;
&lt;br /&gt;
Retirar uma descrição em uma porta do switch&lt;br /&gt;
 unconfigure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; description-string&lt;br /&gt;
&lt;br /&gt;
=== Nodealias ===&lt;br /&gt;
Utilize o comando para ter informações mais completas de uso das portas (mac, ip, vlan, etc). Não colocar as portas de link, para melhor localizar o equipamento dentro da topologia utilizada.&lt;br /&gt;
Também o número de maxentries é 8192 para todo o dispositivo, ou seja é o número máximo que é armazenado por slot, por exemplo, para um stack com 7 switches o valor para maxentries deveria ficar em torno de &#039;48&#039;.&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 configure nodealias ports [port_list | all] maxentries entries&lt;br /&gt;
 enable nodealias port [port_list | all]&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 show nodealias port all&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 show nodealias ip &#039;&#039;ENDEREÇO_IP&#039;&#039;&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
Para desfazer as configurações utilize:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
clear nodealias { ports [port_list | all] | alias-id alias_id }&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== VLANS ===&lt;br /&gt;
Criar VLAN&lt;br /&gt;
&lt;br /&gt;
 create vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; tag &#039;&#039;NUMERO_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Adicionar porta(s) a uma VLAN&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; add port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; [tagged | untagged]&lt;br /&gt;
&lt;br /&gt;
Verificar qual VLAN uma(s) porta pertence&lt;br /&gt;
&lt;br /&gt;
 show vlan port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; vlan&lt;br /&gt;
&lt;br /&gt;
=== Configurações de Rede / IP ===&lt;br /&gt;
Configurar um IP em uma VLAN do Switch&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; ipaddress &#039;&#039;ENDEREÇO_IP/MASCARA_CIDR&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Configurar gateway padrão&lt;br /&gt;
 configure iproute add default &#039;&#039;IP_DO_GATEWAY&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Verificar rotas&lt;br /&gt;
&lt;br /&gt;
 show iproute&lt;br /&gt;
&lt;br /&gt;
Configurar o servidor DNS&lt;br /&gt;
 configure dns-client add name-server &#039;&#039;IP_DO_DNS&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== DHCP Server no Switch ===&lt;br /&gt;
&lt;br /&gt;
Configurar um IP em uma VLAN do Switch. Será o gateway do DHCP.&lt;br /&gt;
&lt;br /&gt;
Habilitar o servidor DHCP e defina o intervalo de endereços IP que o servidor DHCP irá distribuir.&lt;br /&gt;
 enable dhcp vlan &amp;lt;nome&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-address-range &amp;lt;ip_inicial&amp;gt; - &amp;lt;ip_final&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-lease-timer &amp;lt;tempo_lease&amp;gt;&lt;br /&gt;
Configurar Opções Adicionais de DHCP&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-options default-gateway &amp;lt;ip_gateway&amp;gt;&lt;br /&gt;
 configure vlan &amp;lt;nome&amp;gt; dhcp-options dns-server primary &amp;lt;ip_dns&amp;gt;&lt;br /&gt;
 enable dhcp ports &amp;lt;num_porta&amp;gt; vlan &amp;lt;nome&amp;gt; &lt;br /&gt;
Para consultar a tabela de alocação:&lt;br /&gt;
&lt;br /&gt;
 show vlan &amp;lt;nome&amp;gt; dhcp-address-allocation&lt;br /&gt;
&lt;br /&gt;
===Comandos (SHOW) para verificações de configurações ===&lt;br /&gt;
 show accounts&lt;br /&gt;
&lt;br /&gt;
 show configuration&lt;br /&gt;
&lt;br /&gt;
 show version&lt;br /&gt;
&lt;br /&gt;
 show version images&lt;br /&gt;
&lt;br /&gt;
 show system&lt;br /&gt;
&lt;br /&gt;
 show switch&lt;br /&gt;
&lt;br /&gt;
 show switch management&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Verifica portas agregadas&lt;br /&gt;
 show sharing&lt;br /&gt;
&lt;br /&gt;
 show licenses&lt;br /&gt;
&lt;br /&gt;
 show time&lt;br /&gt;
&lt;br /&gt;
 show log&lt;br /&gt;
&lt;br /&gt;
 show vlan&lt;br /&gt;
&lt;br /&gt;
 show vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;PORTA&#039;&#039; no-refresh&lt;br /&gt;
&lt;br /&gt;
 show cli journal&lt;br /&gt;
&lt;br /&gt;
 history&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Verificar se o equipamento esta sendo gerenciado pela Cloud&lt;br /&gt;
 show iqagent&lt;br /&gt;
&lt;br /&gt;
 show iqagent discovery detail&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Mostra tabela ARP&lt;br /&gt;
 show iparp&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Mostra informações de status (up/down) das portas&lt;br /&gt;
 show ports information detail | include Port:|Link\sState:|Link\sUps:|Link\sDowns&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Monitorar o tráfego de entrada e saída de uma VLAN&lt;br /&gt;
Habilitar o monitoramento na VLAN desejada:&lt;br /&gt;
 configure ports all monitor vlan &amp;lt;vlan_name&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Ver as informações da VLAN:&lt;br /&gt;
 show vlan statistics no-refresh&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==== Tabelas MAC / VLAN / Portas ====&lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;ENDERECO_MAC&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Para obter informações de mais do que um endereço, coloque os mac&#039;s entre aspas duplas, separados por um pipe &#039;|&#039;, por exemplo:&lt;br /&gt;
&lt;br /&gt;
 show fdb | include &amp;quot;ENDERECO_MAC1|ENDERECO_MAC2|ENDERECO_MAC3|....&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;PORTA_DO_SWITCH&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 show fdb vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== Empilhamento ===&lt;br /&gt;
&lt;br /&gt;
Para configurar uma nova pilha:&lt;br /&gt;
&lt;br /&gt;
1- Conecte fisicamente os nós usando as portas de empilhamento.&lt;br /&gt;
&lt;br /&gt;
2- Ligue os nós.&lt;br /&gt;
&lt;br /&gt;
3- Para cada switch no qual as portas de stacking ainda não estão ativadas, emita o comando:&lt;br /&gt;
&lt;br /&gt;
 enable stacking-support&lt;br /&gt;
&lt;br /&gt;
4- Verifique se todos os switches têm o mesmo protocolo de empilhamento e suporte&lt;br /&gt;
de empilhamento configurados.&lt;br /&gt;
&lt;br /&gt;
5- Efetue login em qualquer um dos nós através da porta do console, de preferência&lt;br /&gt;
aquela que você deseja usar como mestre. Se você planeja usar o Easy Setup, efetue&lt;br /&gt;
login no nó Master pretendido. Se a pilha for uma nova pilha, os parâmetros padrão&lt;br /&gt;
estão em vigor.&lt;br /&gt;
&lt;br /&gt;
6- Para verificar a pilha digite:&lt;br /&gt;
 show stacking&lt;br /&gt;
O comando “show stacking” exibe todos os nós na pilha. Todos os nós estão em um estado desativado e todos os nós aparecem como nós principais.&lt;br /&gt;
&lt;br /&gt;
7- Digite no switch Master.&lt;br /&gt;
 enable stacking&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Nota:&#039;&#039;&#039; &#039;&#039;Todos os switches devem ter o suporte de empilhamento ativado, mas&lt;br /&gt;
desabilitado, antes de executar o Easy Setup.&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
8- Este comando apresenta a opção de usar o procedimento de instalação fácil. Digite&lt;br /&gt;
 configure stacking easy-setup&lt;br /&gt;
&lt;br /&gt;
9- Reinicie o stack e digite:&lt;br /&gt;
 reboot stack-topology&lt;br /&gt;
&lt;br /&gt;
A configuração é definida como&lt;br /&gt;
valores padrão ao entrar no modo de empilhamento, portanto, todas as informações de&lt;br /&gt;
configuração inseridas anteriormente (exceto os parâmetros de empilhamento com&lt;br /&gt;
base na NVRAM, a imagem selecionada e as informações da conta à prova de falhas) não&lt;br /&gt;
estão disponíveis.&lt;br /&gt;
10- Faça login no nó Master pretendido e verifique os comandos do tipo de pilha &lt;br /&gt;
 show stacking&lt;br /&gt;
 show slot &lt;br /&gt;
 show stacking configuration&lt;br /&gt;
&lt;br /&gt;
11- Se a configuração da pilha for bem-sucedida:&lt;br /&gt;
- Todos os nós são visíveis na pilha.&lt;br /&gt;
- Todos os nós passam para o estado ativo.&lt;br /&gt;
- Algum tempo depois que os nós se tornam ativos, cada nó está presente no slot configurado.&lt;br /&gt;
- Depois que as funções são finalizadas, você pode ver um nó Master e um nó backup.&lt;br /&gt;
12- Verifique se o nó Master é o que você pretendia ser o Master.&lt;br /&gt;
&lt;br /&gt;
=== PoE ===&lt;br /&gt;
&lt;br /&gt;
PoE vem habilitado por padrão nos switches Extreme, para desabilitar, utilize os comandos:&lt;br /&gt;
&lt;br /&gt;
 disable inline-power&lt;br /&gt;
&lt;br /&gt;
 disable inline-power slot &amp;lt;slot&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 disable inline-power ports &amp;lt;port&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Verificando estatísticas da porta visando identificar problemas&lt;br /&gt;
&lt;br /&gt;
 show inline-power&lt;br /&gt;
 show inline-power configuration ports&lt;br /&gt;
 show inline-power info detail ports&lt;br /&gt;
 show inline-power stats ports&lt;br /&gt;
&lt;br /&gt;
O comando de &amp;quot;stats&amp;quot; possibilita identificar a classe do PD (Powered Device) definida em IEEE 802.3 (802.3af, 802.3at, 802.3bt) e associadas com níveis de potência específicas :&lt;br /&gt;
&lt;br /&gt;
    Class 0: Default for Type 1 PDs (802.3af), up to 13W.&lt;br /&gt;
    Class 1: Type 1 PD (802.3af), up to 3.84W.&lt;br /&gt;
    Class 2: Type 1 PD (802.3af), up to 6.49W.&lt;br /&gt;
    Class 3: Type 1 PD (802.3af), up to 13W.&lt;br /&gt;
    Class 4: Type 2 PD (802.3at PoE+), up to 25.5W.&lt;br /&gt;
    Class 5: Type 3 PD (802.3bt), up to 40W.&lt;br /&gt;
    Class 6: Type 3 PD (802.3bt), up to 51W.&lt;br /&gt;
    Class 7: Type 4 PD (802.3bt), up to 62W.&lt;br /&gt;
    Class 8: Type 4 PD (802.3bt), up to 71.3W.&lt;br /&gt;
&lt;br /&gt;
Por exemplo:&lt;br /&gt;
 # show inline-power stats ports 1:1-6&lt;br /&gt;
&lt;br /&gt;
                                STATISTICS COUNTERS&lt;br /&gt;
 Port     State         Class     Absent  InvSig   Denied    OverCurrent   Short&lt;br /&gt;
 1:1      delivering    class4        0       0       6          0             0&lt;br /&gt;
 1:2      searching     ------      113       0     118          0             0&lt;br /&gt;
 1:3      searching     ------        0     234       0          0             0&lt;br /&gt;
 1:4      searching     ------        0     226       0          0             0&lt;br /&gt;
 1:5      delivering    class2        1       5       7          0             0&lt;br /&gt;
 1:6      delivering    class2        0       0       6          0             0&lt;br /&gt;
&lt;br /&gt;
As colunas representam:&lt;br /&gt;
&lt;br /&gt;
#Absent: Exibe o número de vezes que a porta foi desconectada.&lt;br /&gt;
#InvSig: Exibe o número de vezes que a porta tinha uma assinatura inválida.&lt;br /&gt;
#Denied: Exibe o número de vezes que a porta foi negada.&lt;br /&gt;
#Over-current: Exibe o número de vezes que a porta entrou em um estado de sobrecorrente.&lt;br /&gt;
#Short: Exibe o número de vezes que a porta entrou no estado de corrente.&lt;br /&gt;
&lt;br /&gt;
(Fonte: https://documentation.extremenetworks.com/switchengine_commands_32.2/downloads/SwitchEngine_Command_Reference_32.2.pdf)&lt;br /&gt;
&lt;br /&gt;
===SNMP===&lt;br /&gt;
Desabilitar os protocolos SNMPv1/v2c&lt;br /&gt;
 disable snmp access snmp-v1v2c&lt;br /&gt;
&lt;br /&gt;
Configurar informações básicas do dispositivo&lt;br /&gt;
 configure snmp sysName &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysLocation &#039;&#039;LOCALIZAÇÃO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysContact &#039;&#039;CONTATO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Habilitar SNMPv3&lt;br /&gt;
 enable snmp access snmpv3&lt;br /&gt;
&lt;br /&gt;
Adicionar usuário SNMP&lt;br /&gt;
 configure snmpv3 add user &#039;&#039;USUARIO&#039;&#039;&lt;br /&gt;
                          {authentication [md5 | sha] &#039;&#039;SENHA_DE_AUTENTICAÇAO&#039;&#039;}&lt;br /&gt;
                          {privacy {des | 3des | aes {128 | 192 | 256}} &#039;&#039;SENHA_PRIVADA&#039;&#039;}&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add group &#039;&#039;NOME_DO_GRUPO&#039;&#039; user &#039;&#039;USUARIO&#039;&#039; sec-model usm&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add access &#039;&#039;NOME_DO_GRUPO&#039;&#039; sec-model usm sec-level &lt;br /&gt;
                  [noauth | authnopriv | priv] {read-view read_view_name} {write-viewwrite_view_name} {notify-view notify_view_name}&lt;br /&gt;
&lt;br /&gt;
===Diagnóstico de Cabos de Rede===&lt;br /&gt;
Para realizar o diagnóstico do cabo de rede&lt;br /&gt;
 run diagnostics cable ports &amp;lt;port&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Analise os resultados:&lt;br /&gt;
 Ok: Sem falhas detectadas.&lt;br /&gt;
 Open: Cabo desconectado, com quebra física ou má terminação.&lt;br /&gt;
 Short: Curto-circuito nos pares do cabo.&lt;br /&gt;
 Hi Imp / Low Imp: Problemas de impedância ou conector defeituoso. &lt;br /&gt;
&lt;br /&gt;
Diagnóstico de Hardware Geral (Extended)&lt;br /&gt;
Se a suspeita for um problema físico no módulo de fibra ou porta em si:&lt;br /&gt;
 run diagnostics extended.&lt;br /&gt;
Nota: Este comando pode interromper o tráfego por até 15 minutos. &lt;br /&gt;
&lt;br /&gt;
Diagnóstico de Fibra Óptica&lt;br /&gt;
Como o run diagnostics cable não funciona em fibra, para validar conectividade óptica, utilize: &lt;br /&gt;
 show port &amp;lt;port&amp;gt; information detail (Verifique se há luz/sinal e erros de CRC).&lt;br /&gt;
 show transceiver (Verifique a potência de recepção/transmissão - Tx/Rx power). &lt;br /&gt;
&lt;br /&gt;
Dica: O uso desse comando pode impactar o tráfego nas portas testadas temporariamente&lt;br /&gt;
&lt;br /&gt;
Para informações de diagnóstico detalhadas para transceivers ópticos, incluindo fabricante, serial, presença de sinal e status de falha de transmissão.&lt;br /&gt;
 debug hal show optic-info port-list 1:30&lt;br /&gt;
Analise do resultado:&lt;br /&gt;
 Port                       1:30&lt;br /&gt;
 SFP or SFP+ or SFP28:      SFP+&lt;br /&gt;
 Signal:                    present&lt;br /&gt;
 TX Fault:                  no&lt;br /&gt;
 Vendor:                    FORMERICAOE&lt;br /&gt;
 oui:                       00-00-00&lt;br /&gt;
 Part Number:               TAS-A1NB1-FAHM&lt;br /&gt;
 Serial Number:             23088-92224&lt;br /&gt;
 Manufacture Date:          230559&lt;br /&gt;
 Revision:&lt;br /&gt;
 SFP/SFP-DD/SFP+/SFP28 Type:SFP/SFP+/SFP28&lt;br /&gt;
 Connector:                 LC(7)&lt;br /&gt;
 Type:                      LR&lt;br /&gt;
 Supported:                 yes&lt;br /&gt;
 Wavelength:                1310&lt;br /&gt;
 Options[0]:                0x00&lt;br /&gt;
 Options[1]:                0x1a&lt;br /&gt;
 GBIC supports DDMI.  MonitorType: 68&lt;br /&gt;
&lt;br /&gt;
===Desinstalar licenças de avaliação===&lt;br /&gt;
Siga o processo descrito em: https://extreme-networks.my.site.com/ExtrArticleDetail?an=000092952&lt;br /&gt;
&lt;br /&gt;
== Segurança ==&lt;br /&gt;
&lt;br /&gt;
=== Habilitar Logs ===&lt;br /&gt;
 enable log target session&lt;br /&gt;
&lt;br /&gt;
 configure syslog add [ipaddress {udp-port {udp_port}} | ipPort | ipaddress tls_port {tls_port}] {vr vr_name} [local0...local7]&lt;br /&gt;
&lt;br /&gt;
 enable syslog&lt;br /&gt;
&lt;br /&gt;
==== Registrar alterações no Log ====&lt;br /&gt;
&lt;br /&gt;
Permite registrar em Log as mudanças de configuração, assim como quem realizou a modificação. Útil para fins de auditoria.&lt;br /&gt;
&lt;br /&gt;
  enable cli config-logging&lt;br /&gt;
&lt;br /&gt;
=== Habilitar Port-Security/MAC Locking ===&lt;br /&gt;
&lt;br /&gt;
MAC Locking, ou bloqueio de MAC, é uma funcionalidade que permite a um switch aprender e armazenar os endereços MAC dos dispositivos conectados a suas portas. Uma vez que um endereço MAC é aprendido, o switch pode bloquear a porta para novos dispositivos, impedindo conexões não autorizadas.&lt;br /&gt;
 configure mac-locking ports &amp;lt;num_porta&amp;gt; first-arrival limit-learning &amp;lt;limite_de_MACs_na_porta&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== DHCP/BOOTP Relay ===&lt;br /&gt;
&lt;br /&gt;
 enable bootprelay {{vlan} vlan_name | {{vr} vr_name} | all [{vr} vr_name]}&lt;br /&gt;
&lt;br /&gt;
 configure bootprelay {vlan &#039;&#039;NOME_DA_VLAN_DO_DHCP_SERVER&#039;&#039;} add &#039;&#039;IP_DO_DHCP&#039;&#039; {vr vrid}&lt;br /&gt;
&lt;br /&gt;
Verificar as configurações de DHCP/BootRelay&lt;br /&gt;
&lt;br /&gt;
 show bootprelay configuration&lt;br /&gt;
&lt;br /&gt;
 show configuration nettools&lt;br /&gt;
&lt;br /&gt;
=== DHCP Snooping ===&lt;br /&gt;
&lt;br /&gt;
 enable ip-security dhcp-snooping vlan &#039;&#039;ID_DA_VLAN&#039;&#039; port [&#039;&#039;all&#039;&#039; | &#039;&#039;PORTA(S)&#039;&#039;] violation-action none&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Configure trusted ports (uplink port for DHCP Server)&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 configure trusted-ports &#039;&#039;PORTAS_DE_UPLINK&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
 configure trusted-servers vlan &#039;&#039;ID_DA_VLAN_DO_DHCP_SERVER&#039;&#039; add server &#039;&#039;IP_DO_DHCP&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
=== Como Criar ACLs ===&lt;br /&gt;
&lt;br /&gt;
[https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html]&lt;br /&gt;
&lt;br /&gt;
=== Netlogin ===&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000080274 https://extremeportal.force.com/ExtrArticleDetail?an=000080274]&lt;br /&gt;
&lt;br /&gt;
[https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402 https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402 https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin]&lt;br /&gt;
&lt;br /&gt;
[https://github.com/dwinurhadia/freeradius-macauth https://github.com/dwinurhadia/freeradius-macauth]&lt;br /&gt;
&lt;br /&gt;
[https://wiki.freeradius.org/guide/Mac-Auth https://wiki.freeradius.org/guide/Mac-Auth]&lt;br /&gt;
&lt;br /&gt;
=== Configurando o MAC-BASED VLAN ===&lt;br /&gt;
1. Primeiro deve-se criar a VLAN temporária que o netlogin irá utilizar para &amp;quot;conversar com o Radius&amp;quot; e, também, a VLAN que será utilizada para atribuir IPs para os computadores:&lt;br /&gt;
&lt;br /&gt;
  create vlan &amp;quot;NET_LOGIN&amp;quot;&lt;br /&gt;
  create vlan &amp;quot;REDE_187&amp;quot;&lt;br /&gt;
  configure vlan REDE_187 tag 187&lt;br /&gt;
  configure REDE_187 add ports 24 tagged&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
2. Configurar a autenticação das portas para o netlogin:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin vlan NET_LOGIN&lt;br /&gt;
  enable netlogin dot1x mac&lt;br /&gt;
  configure netlogin mac authentication database-order radius&lt;br /&gt;
  enable netlogin ports 1-23 mac&lt;br /&gt;
  configure netlogin ports 1-23 mode port-based-vlans&lt;br /&gt;
  configure netlogin ports 1-23 no-restart&lt;br /&gt;
  configure netlogin add mac-list ff:ff:ff:ff:ff:ff 48&lt;br /&gt;
&lt;br /&gt;
Obs: o mac-list informado refere-se ao broadcast do MAC address e o valor &amp;quot;48&amp;quot; ao tamanho em bits&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
3. Configurar a autenticação do Radius:&lt;br /&gt;
&lt;br /&gt;
  configure radius mgmt-access primary server 200.145.x.y 1812 client-ip 172.31.x.y vr VR-Default&lt;br /&gt;
  configure radius mgmt-access primary shared-secret encrypted &amp;quot;#$8VnrPisKgrhPOCh2WEepV==&amp;quot;&lt;br /&gt;
  configure radius netlogin primary server 200.145.x.y 1812 client-ip 172.31.x.y vr VR-Default&lt;br /&gt;
  configure radius netlogin primary shared-secret encrypted &amp;quot;#$kyGEk8PK4BbzEV+WJdapp16A==&amp;quot;&lt;br /&gt;
  enable radius&lt;br /&gt;
  enable radius mgmt-access&lt;br /&gt;
  enable radius netlogin&lt;br /&gt;
&lt;br /&gt;
Obs: o endereço &amp;quot;primary server&amp;quot; é o servidor do radius, a porta &amp;quot;1812&amp;quot; é a porta padrão do Authentication. A shared-secret é gerada com o comando &#039;&#039;configure radius mgmt-access/netlogin primary shared-secret&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
4. Quando não há conexão disponível com o PFSense irá direcionar para a VLAN especificada, ideal é uma VLAN com acesso restrito:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin authentication failure vlan VLAN_restrita ports 1-23&lt;br /&gt;
  configure netlogin authentication service-unavailable vlan VLAN_restrita ports 1-23&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
5. Configuracao para reautenticacao do mac em segundos:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin mac ports all timers reauth-period 60&lt;br /&gt;
  configure netlogin mac ports all timers reauthentication on&lt;br /&gt;
&lt;br /&gt;
Após inserir esta opção, não é possível tirar, apenas desabilitar:&lt;br /&gt;
&lt;br /&gt;
  configure netlogin mac ports 1-23 timers reauth-period 3600 reauthentication off&lt;br /&gt;
  configure netlogin mac timers reauth-period 0&lt;br /&gt;
  configure netlogin session-timeout mac 0&lt;br /&gt;
&lt;br /&gt;
6. Para retirar a configuração do NETLOGIN de alguma porta:&lt;br /&gt;
&lt;br /&gt;
  disable netlogin ports &amp;lt;portas&amp;gt; mac&lt;br /&gt;
&lt;br /&gt;
=== Configurando PFSense ===&lt;br /&gt;
1. No FreeRADIUS, na opção Users inserir as informações de conexão para o computador (MAC-Address, senha), além deste usuário, também é necessário criar o usuário de conexão da switch com a senha:&lt;br /&gt;
&lt;br /&gt;
2. No campo Additional RADIUS Attributes (REPLY-ITEM) inserir o comando &amp;quot;Extreme-Netlogin-Extended-VLAN = U187&amp;quot;, onde a letra U é para representar que esta é a VLAN do usuário e o número é a tag da VLAN:&lt;br /&gt;
&lt;br /&gt;
3. Em NAS/Clients inserir o endereço IP do SiteEngine (186.217.0.16) em Client IP Address, inserir a senha da switch em Client Shared Secret e no campo NAS Login informar o nome de usuário para conexão da switch.&lt;br /&gt;
&lt;br /&gt;
4. Na opção Interfaces inserir as informações de Authentication, Accounting e Status (IP e Porta Padrão)&lt;br /&gt;
&lt;br /&gt;
=== ELRP e STP ===&lt;br /&gt;
&lt;br /&gt;
Extreme Loop Recovery Protocol (ELRP) é um protocolo proprietário que detecta loops de rede na Camada 2. O ELRP envia uma PDU especial pela VLAN e detecta um loop se o remetente switch recebe a mesma PDU de volta&lt;br /&gt;
&lt;br /&gt;
1) Sugestão: Criar uma VLAN para aplicar o ELRP e STP. Ela não precisa existir na rede:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
create vlan STPDOMAIN tag 4000&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
2) Ativando o ELRP:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
enable elrp-client&lt;br /&gt;
configure elrp-client periodic vlan STPDOMAIN ports all disable-port duration 60&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
3) Configurando o stpd s0:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
disable stpd s0&lt;br /&gt;
configure stpd s0 mode dot1w&lt;br /&gt;
enable stpd s0 rapid-root-failover&lt;br /&gt;
enable stpd s0 auto-bind vlan STPDOMAIN&lt;br /&gt;
&lt;br /&gt;
configure stpd s0 ports link-type edge 1:1-24&lt;br /&gt;
configure stpd s0 ports edge-safeguard enable 1:1-24 recovery-timeout 60&lt;br /&gt;
configure stpd s0 ports bpdu-restrict enable 1:1-24 recovery-timeout 60&lt;br /&gt;
configure stpd s0 ports restricted-tcn on 1:1-24&lt;br /&gt;
&lt;br /&gt;
configure stpd s0 tag 4000&lt;br /&gt;
enable stpd s0&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* link-type edge: Define o tipo da porta [[auto | broadcast | point-to-point] port_list | edge port_list {edge-safeguard [enable | disable] {bpdu-restrict} {recovery-timeout seconds}}]&lt;br /&gt;
* edge-safeguard: - Previne LOOP no STPD&lt;br /&gt;
* bpdu-restrict: Impede que transmitido pacote BPDU nas portas (ligar outra Switch)&lt;br /&gt;
* restricted-tcn: Impede a propagação de BPDUs TCN na porta&lt;br /&gt;
&amp;lt;b&amp;gt;Se for realizar uplink via UTP, é necessário alterar as configurações acima para evitar que a porta seja desativada&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Para desabilitar BPDU nas portas:&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports link-type auto &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports edge-safeguard disable &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 configure stpd s0 ports bpdu-restrict disable &amp;lt;port_list&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== Bloqueio de endereços mac-ddress ===&lt;br /&gt;
&lt;br /&gt;
1. Pode ser utilizado o comando a seguir para criar uma lista BLACKHOLE, quando o bloqueio é específico dentro de uma VLAN:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
create fdb 01:00:5E:00:E0:00 vlan vlan_name [ports port_list | blackhole]&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
Para excluir utilize:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
delete fdb [all | mac_address [vlan vlan_name ] &lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
2. Caso o bloqueio desejado seja para qualquer VLAN existente, pode-se criar uma regra ACL:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
entry block_MAC {&lt;br /&gt;
      if { ethernet-source-address 01:00:5E:00:E0:00; } then { deny; }&lt;br /&gt;
}&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;/div&gt;</summary>
		<author><name>Guilherme.marques</name></author>
	</entry>
	<entry>
		<id>https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=46</id>
		<title>Switch Extreme</title>
		<link rel="alternate" type="text/html" href="https://wiki-ti.unesp.br/index.php?title=Switch_Extreme&amp;diff=46"/>
		<updated>2023-10-09T14:51:32Z</updated>

		<summary type="html">&lt;p&gt;Guilherme.marques: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Configuração Serial ==&lt;br /&gt;
&lt;br /&gt;
 Speed Bus: &#039;&#039;&#039;115200&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Comandos ==&lt;br /&gt;
&lt;br /&gt;
===Configurações Básicas===&lt;br /&gt;
 &lt;br /&gt;
Apaga todas as configurações do Switch&lt;br /&gt;
 unconfigure switch all&lt;br /&gt;
&lt;br /&gt;
Habilitar SSH&lt;br /&gt;
 enable ssh2&lt;br /&gt;
&lt;br /&gt;
Desabilitar Telnet&lt;br /&gt;
 disalbe telnet&lt;br /&gt;
&lt;br /&gt;
Remover todas as portas da VLAN default&lt;br /&gt;
&lt;br /&gt;
 configure vlan Default delete ports all&lt;br /&gt;
&lt;br /&gt;
Configurar o nome do Switch&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysname &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Salvar configurações&lt;br /&gt;
&lt;br /&gt;
 save&lt;br /&gt;
&lt;br /&gt;
==== SNTP ====&lt;br /&gt;
&lt;br /&gt;
 enable sntp-client &lt;br /&gt;
&lt;br /&gt;
 configure sntp-client primary &#039;&#039;IP_DO_SERVIDOR_NTP&#039;&#039; vr VR-Default&lt;br /&gt;
&lt;br /&gt;
 configure sntp-client update-interval 30&lt;br /&gt;
&lt;br /&gt;
Definir TimeZone do Brasil&lt;br /&gt;
&lt;br /&gt;
configure timezone name BRTZ -180 noautodst&lt;br /&gt;
&lt;br /&gt;
Horário de verão&lt;br /&gt;
&lt;br /&gt;
 configure timezone name BRTZ -180 autodst name DST 0 begins every third sunday october at 0 0 ends every third sunday february at 0 0&lt;br /&gt;
&lt;br /&gt;
=== Configuração de Portas ===&lt;br /&gt;
&lt;br /&gt;
Ativar porta&lt;br /&gt;
&lt;br /&gt;
 enable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Desativar uma porta&lt;br /&gt;
&lt;br /&gt;
 disable port &#039;&#039;NUMERO_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Colocar um rótulo em uma porta do switch&lt;br /&gt;
 configure port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; display-string &#039;&#039;NOME_DA_PORTA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Informações detalhadas de porta&lt;br /&gt;
&lt;br /&gt;
  show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; information detail&lt;br /&gt;
&lt;br /&gt;
==== Nodealias ====&lt;br /&gt;
 enable nodealias port all&lt;br /&gt;
&lt;br /&gt;
 show nodealias port all&lt;br /&gt;
&lt;br /&gt;
 show nodealias ip &#039;&#039;ENDEREÇO_IP&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== VLANS ===&lt;br /&gt;
Criar VLAN&lt;br /&gt;
&lt;br /&gt;
 create vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; tag &#039;&#039;NUMERO_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Adicionar porta(s) a uma VLAN&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; add port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; [tagged | untagged]&lt;br /&gt;
&lt;br /&gt;
Verificar qual VLAN uma(s) porta pertence&lt;br /&gt;
&lt;br /&gt;
 show vlan port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;NUMERO_DA_PORTA&#039;&#039; ou &#039;&#039;NUMEROS_DAS_PORTAS_SEPARADOS_POR_VIRGULA&#039;&#039; vlan&lt;br /&gt;
&lt;br /&gt;
=== Configurações de Rede / IP ===&lt;br /&gt;
Configurar um IP em uma VLAN do Switch&lt;br /&gt;
&lt;br /&gt;
 configure vlan &#039;&#039;NOME_DA_VLAN&#039;&#039; ipaddress &#039;&#039;ENDEREÇO_IP/MASCARA_CIDR&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Configurar gateway padrão&lt;br /&gt;
 configure iproute add default &#039;&#039;IP_DO_GATEWAY&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Verificar rotas&lt;br /&gt;
&lt;br /&gt;
 show iproute&lt;br /&gt;
&lt;br /&gt;
Configurar o servidor DNS&lt;br /&gt;
 configure dns-client add name-server &#039;&#039;IP_DO_DNS&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
===Comandos para verificações de configurações ===&lt;br /&gt;
 show accounts&lt;br /&gt;
&lt;br /&gt;
 show configuration&lt;br /&gt;
&lt;br /&gt;
 show version&lt;br /&gt;
&lt;br /&gt;
 show version images&lt;br /&gt;
&lt;br /&gt;
 show system&lt;br /&gt;
&lt;br /&gt;
 show switch&lt;br /&gt;
&lt;br /&gt;
 show switch management&lt;br /&gt;
&lt;br /&gt;
Verifica portas agregadas&lt;br /&gt;
 show sharing&lt;br /&gt;
&lt;br /&gt;
 show licenses&lt;br /&gt;
&lt;br /&gt;
 show time&lt;br /&gt;
&lt;br /&gt;
 show log&lt;br /&gt;
&lt;br /&gt;
 show vlan&lt;br /&gt;
&lt;br /&gt;
 show vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 show port &#039;&#039;PORTA&#039;&#039; no-refresh&lt;br /&gt;
&lt;br /&gt;
 show cli journal&lt;br /&gt;
&lt;br /&gt;
 history&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Verificar se o equipamento esta sendo gerenciado pela Cloud&lt;br /&gt;
 show iqagent&lt;br /&gt;
&lt;br /&gt;
 show iqagent discovery detail&lt;br /&gt;
&lt;br /&gt;
==== Tabelas MAC / VLAN / Portas ====&lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;ENDERECO_MAC&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 show fdb &#039;&#039;PORTA_DO_SWITCH&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 show fdb vlan &#039;&#039;NOME_DA_VLAN&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
----&lt;br /&gt;
Mostra tabela ARP&lt;br /&gt;
 show iparp&lt;br /&gt;
&lt;br /&gt;
=== Empilhamento ===&lt;br /&gt;
&lt;br /&gt;
Para configurar uma nova pilha:&lt;br /&gt;
&lt;br /&gt;
1- Conecte fisicamente os nós usando as portas de empilhamento.&lt;br /&gt;
&lt;br /&gt;
2- Ligue os nós.&lt;br /&gt;
&lt;br /&gt;
3- Para cada switch no qual as portas de stacking ainda não estão ativadas, emita o comando:&lt;br /&gt;
&lt;br /&gt;
 enable stacking-support&lt;br /&gt;
&lt;br /&gt;
4- Verifique se todos os switches têm o mesmo protocolo de empilhamento e suporte&lt;br /&gt;
de empilhamento configurados.&lt;br /&gt;
&lt;br /&gt;
5- Efetue login em qualquer um dos nós através da porta do console, de preferência&lt;br /&gt;
aquela que você deseja usar como mestre. Se você planeja usar o Easy Setup, efetue&lt;br /&gt;
login no nó Master pretendido. Se a pilha for uma nova pilha, os parâmetros padrão&lt;br /&gt;
estão em vigor.&lt;br /&gt;
&lt;br /&gt;
6- Para verificar a pilha digite:&lt;br /&gt;
 show stacking&lt;br /&gt;
O comando “show stacking” exibe todos os nós na pilha. Todos os nós estão em um estado desativado e todos os nós aparecem como nós principais.&lt;br /&gt;
&lt;br /&gt;
7- Digite no switch Master.&lt;br /&gt;
 enable stacking&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Nota:&#039;&#039;&#039; &#039;&#039;Todos os switches devem ter o suporte de empilhamento ativado, mas&lt;br /&gt;
desabilitado, antes de executar o Easy Setup.&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
8- Este comando apresenta a opção de usar o procedimento de instalação fácil. Digite&lt;br /&gt;
 configure stacking easy-setup&lt;br /&gt;
&lt;br /&gt;
9- Reinicie o stack e digite:&lt;br /&gt;
 reboot stack-topology&lt;br /&gt;
&lt;br /&gt;
A configuração é definida como&lt;br /&gt;
valores padrão ao entrar no modo de empilhamento, portanto, todas as informações de&lt;br /&gt;
configuração inseridas anteriormente (exceto os parâmetros de empilhamento com&lt;br /&gt;
base na NVRAM, a imagem selecionada e as informações da conta à prova de falhas) não&lt;br /&gt;
estão disponíveis.&lt;br /&gt;
10- Faça login no nó Master pretendido e verifique os comandos do tipo de pilha &lt;br /&gt;
 show stacking&lt;br /&gt;
 show slot &lt;br /&gt;
 show stacking configuration&lt;br /&gt;
&lt;br /&gt;
11- Se a configuração da pilha for bem-sucedida:&lt;br /&gt;
- Todos os nós são visíveis na pilha.&lt;br /&gt;
- Todos os nós passam para o estado ativo.&lt;br /&gt;
- Algum tempo depois que os nós se tornam ativos, cada nó está presente no slot configurado.&lt;br /&gt;
- Depois que as funções são finalizadas, você pode ver um nó Master e um nó backup.&lt;br /&gt;
12- Verifique se o nó Master é o que você pretendia ser o Master.&lt;br /&gt;
&lt;br /&gt;
=== PoE ===&lt;br /&gt;
&lt;br /&gt;
PoE vem habilitado por padrão nos switches Extreme, para desabilitar, utilize os comandos:&lt;br /&gt;
&lt;br /&gt;
 disable inline-power&lt;br /&gt;
&lt;br /&gt;
 disable inline-power slot &amp;lt;slot&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 disable inline-power ports &amp;lt;port&amp;gt;&lt;br /&gt;
&lt;br /&gt;
===SNMP===&lt;br /&gt;
Desabilitar os protocolos SNMPv1/v2c&lt;br /&gt;
 disable snmp access snmp-v1v2c&lt;br /&gt;
&lt;br /&gt;
Configurar informações básicas do dispositivo&lt;br /&gt;
 configure snmp sysName &#039;&#039;NOME_DO_SWITCH&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysLocation &#039;&#039;LOCALIZAÇÃO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
 configure snmp sysContact &#039;&#039;CONTATO&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Habilitar SNMPv3&lt;br /&gt;
 enable snmp access snmpv3&lt;br /&gt;
&lt;br /&gt;
Adicionar usuário SNMP&lt;br /&gt;
 configure snmpv3 add user &#039;&#039;USUARIO&#039;&#039;&lt;br /&gt;
                          {authentication [md5 | sha] &#039;&#039;SENHA_DE_AUTENTICAÇAO&#039;&#039;}&lt;br /&gt;
                          {privacy {des | 3des | aes {128 | 192 | 256}} &#039;&#039;SENHA_PRIVADA&#039;&#039;}&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add group &#039;&#039;NOME_DO_GRUPO&#039;&#039; user &#039;&#039;USUARIO&#039;&#039; sec-model usm&lt;br /&gt;
&lt;br /&gt;
 configure snmpv3 add access &#039;&#039;NOME_DO_GRUPO&#039;&#039; sec-model usm sec-level &lt;br /&gt;
                  [noauth | authnopriv | priv] {read-view read_view_name} {write-viewwrite_view_name} {notify-view notify_view_name}&lt;br /&gt;
&lt;br /&gt;
== Segurança ==&lt;br /&gt;
&lt;br /&gt;
=== Habilitar Logs ===&lt;br /&gt;
 enable log target session&lt;br /&gt;
&lt;br /&gt;
 configure syslog add [ipaddress {udp-port {udp_port}} | ipPort | ipaddress tls_port {tls_port}] {vr vr_name} [local0...local7]&lt;br /&gt;
&lt;br /&gt;
 enable syslog&lt;br /&gt;
&lt;br /&gt;
=== DHCP/BOOTP Relay ===&lt;br /&gt;
&lt;br /&gt;
 enable bootprelay {{vlan} vlan_name | {{vr} vr_name} | all [{vr} vr_name]}&lt;br /&gt;
&lt;br /&gt;
 configure bootprelay {vlan &#039;&#039;NOME_DA_VLAN_DO_DHCP_SERVER&#039;&#039;} add &#039;&#039;IP_DO_DHCP&#039;&#039; {vr vrid}&lt;br /&gt;
&lt;br /&gt;
Verificar as configurações de DHCP/BootRelay&lt;br /&gt;
&lt;br /&gt;
 show bootprelay configuration&lt;br /&gt;
&lt;br /&gt;
 show configuration nettools&lt;br /&gt;
&lt;br /&gt;
=== DHCP Snooping ===&lt;br /&gt;
&lt;br /&gt;
 enable ip-security dhcp-snooping vlan &#039;&#039;ID_DA_VLAN&#039;&#039; port [&#039;&#039;all&#039;&#039; | &#039;&#039;PORTA(S)&#039;&#039;] violation-action none&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Configure trusted ports (uplink port for DHCP Server)&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
 configure trusted-ports &#039;&#039;PORTAS_DE_UPLINK&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
 configure trusted-servers vlan &#039;&#039;ID_DA_VLAN_DO_DHCP_SERVER&#039;&#039; add server &#039;&#039;IP_DO_DHCP&#039;&#039; trust-for dhcp-server&lt;br /&gt;
&lt;br /&gt;
=== Como Criar ACLs ===&lt;br /&gt;
&lt;br /&gt;
[https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html https://www.analysisman.com/2018/03/extreme-switch-how-to-create-acl-in-exos.html]&lt;br /&gt;
&lt;br /&gt;
=== Netlogin ===&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000080274 https://extremeportal.force.com/ExtrArticleDetail?an=000080274]&lt;br /&gt;
&lt;br /&gt;
[https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402 https://community.extremenetworks.com/t5/extremeswitching-exos-switch/assign-vlan-on-mac-netlogin-with-freeradius/m-p/15894?_ga=2.244646215.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402 https://documentation.extremenetworks.com/exos_31.1/GUID-14557641-C5EE-4E54-B6B2-F26D0C411DCD.shtml?_ga=2.152487547.35807826.1693573402-1617834161.1693573402]&lt;br /&gt;
&lt;br /&gt;
[https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin https://extremeportal.force.com/ExtrArticleDetail?an=000082627&amp;amp;q=mac-based%20netlogin]&lt;br /&gt;
&lt;br /&gt;
[https://github.com/dwinurhadia/freeradius-macauth https://github.com/dwinurhadia/freeradius-macauth]&lt;br /&gt;
&lt;br /&gt;
[https://wiki.freeradius.org/guide/Mac-Auth https://wiki.freeradius.org/guide/Mac-Auth]&lt;/div&gt;</summary>
		<author><name>Guilherme.marques</name></author>
	</entry>
	<entry>
		<id>https://wiki-ti.unesp.br/index.php?title=Categoria:Tutoriais&amp;diff=45</id>
		<title>Categoria:Tutoriais</title>
		<link rel="alternate" type="text/html" href="https://wiki-ti.unesp.br/index.php?title=Categoria:Tutoriais&amp;diff=45"/>
		<updated>2023-09-25T19:27:43Z</updated>

		<summary type="html">&lt;p&gt;Guilherme.marques: Criar página em branco&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Guilherme.marques</name></author>
	</entry>
</feed>